Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Sep;62(3):416-25.
doi: 10.1111/j.1751-1097.1995.tb02362.x.

The use of exogenous fluorescent probes for temperature measurements in single living cells

Affiliations

The use of exogenous fluorescent probes for temperature measurements in single living cells

C F Chapman et al. Photochem Photobiol. 1995 Sep.

Abstract

The fluorescent membrane probes 7-nitrobenz-2-oxa-1,3-diazol-4-yl (NBD) and 6-dodecanoyl-2-dimethylamino-naphthalene (laurdan) have been studied for use as optical thermometers in living cells. The thermal sensitivity of NBD is primarily a consequence of rapid, heat-induced electronic changes, which increase the observed fluorescence decay rate. As a result, fluorescence intensity and lifetime variations of membrane-bound NBD-conjugated phospholipids and fatty acids can be directly correlated with cellular temperature. In contrast, laurdan fluorescence undergoes a dramatic temperature-dependent Stokes shift as the membrane undergoes a gel-to-liquid-crystalline phase transition. This facilitates the use of fluorescence spectra to record the indirect effect of microenvironmental changes, which occur during bilayer heating. Microscope and suspension measurements of cells and phospholipid vesicles are compared for both probes using steady-state and fluorescence lifetime (suspension only) data. Our results show that NBD fluorescence lifetime recordings can provide reasonable temperature resolution (approximately 2 degrees C) over a broad temperature range. Laurdan's microenvironmental sensitivity permits better temperature resolution (0.1-1 degree C) at the expense of a more limited dynamic range that is determined solely by bilayer properties. The temperature sensitivity of NBD is based on rapid intramolecular rotations and vibrations, while laurdan relies on a slower, multistep mechanism involving bilayer rearrangement, water penetration and intermolecular processes. Because of these differences in time scale, NBD appears to be more suitable for monitoring ultrafast phenomena, such as the impact of short-pulse microirradiation on single cells.

PubMed Disclaimer

Publication types

LinkOut - more resources