Quality assurance and quality control of an intensive care unit picture archiving and communication system
- PMID: 8573625
- DOI: 10.1007/BF03168715
Quality assurance and quality control of an intensive care unit picture archiving and communication system
Abstract
Most radiology departments have established quality assurance (QA) and quality control (QC) programs for conventional film-based image management systems. At many institutions, digital image management systems, or picture archiving and communication systems (PACS), are replacing part or all of the film management system. In these situations, it is important to control the quality of the digital images that are produced. The observed frequency of eight types of image-related errors occurring on an image viewing station located in a medical intensive care unit is reported. Images on the viewing station were checked for 12 consecutive weeks. Film images available in the radiology reading room and digital images on the viewing station were compared with a list of completed examinations produced by the radiological information system. Overall, 1,082 patient examinations were encountered. Seventy-six images (7.02% of all images) were observed with errors. In addition, four previously unencountered types of errors were observed in 11 images (1.01% of all images). The majority of the errors are attributed to interfaces either between information systems or between the PACS and the user. It is concluded that QA-QC procedures are necessary for PACS, and that good interfaces, both between information systems and between humans and computer systems, are essential for successful PACS implementations.
Similar articles
-
Continuing quality improvement procedures for a clinical PACS.J Digit Imaging. 1998 Aug;11(3 Suppl 1):111-4. doi: 10.1007/BF03168275. J Digit Imaging. 1998. PMID: 9735446 Free PMC article.
-
Quality assurance of picture archiving communication systems with laser film digitizers.J Digit Imaging. 1991 Nov;4(4):248-50. doi: 10.1007/BF03173907. J Digit Imaging. 1991. PMID: 1772918
-
Integrating digital ICU viewing into the global working environment.Eur J Radiol. 1996 Jun;22(3):221-7. doi: 10.1016/0720-048x(96)00761-9. Eur J Radiol. 1996. PMID: 8832237
-
Picture archiving and communication in radiology.Rays. 2003 Jan-Mar;28(1):73-81. Rays. 2003. PMID: 14509181 Review.
-
Computerized follow-up of discrepancies in image interpretation between emergency and radiology departments.J Digit Imaging. 1998 Aug;11(3 Suppl 1):18-20. doi: 10.1007/BF03168250. J Digit Imaging. 1998. PMID: 9735425 Free PMC article. Review.
Cited by
-
Frequency and impact of high-resolution monitor failure in a filmless imaging department.J Digit Imaging. 2000 Aug;13(3):114-8. doi: 10.1007/BF03168383. J Digit Imaging. 2000. PMID: 15359749 Free PMC article.
-
Digital repeat analysis; setup and operation.J Digit Imaging. 2006 Jun;19(2):159-66. doi: 10.1007/s10278-005-8733-1. J Digit Imaging. 2006. PMID: 16421768 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources