Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children
- PMID: 8575477
- DOI: 10.1007/BF00801613
Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children
Abstract
Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.
Similar articles
-
Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?Eur J Nucl Med. 1998 Jul;25(7):760-5. doi: 10.1007/s002590050280. Eur J Nucl Med. 1998. PMID: 9662599 Clinical Trial.
-
Simultaneous technetium-99 MAG(3), iodine-131-orthoiodohippurate and iodine-125 iothalamate clearance and biodistribution after bolus injection in rats.Biopharm Drug Dispos. 2000 Jul;21(5):181-92. doi: 10.1002/1099-081x(200007)21:5<181::aid-bdd227>3.0.co;2-j. Biopharm Drug Dispos. 2000. PMID: 11180197
-
Effect of renal maturation on the clearance of technetium-99m mercaptoacetyltriglycine.Eur J Nucl Med. 1994 Dec;21(12):1333-7. doi: 10.1007/BF02426698. Eur J Nucl Med. 1994. PMID: 7875172
-
Reproducibility of technetium-99m mercaptoacetyltriglycine clearance in patients with impaired renal function.Nucl Med Commun. 2006 Feb;27(2):191-6. doi: 10.1097/01.mnm.0000195674.75664.ba. Nucl Med Commun. 2006. PMID: 16404234 Clinical Trial.
-
Early mercaptoacetyltriglycine(MAG-3) diuretic renography results after pyeloplasty.BJU Int. 2016 Nov;118(5):790-796. doi: 10.1111/bju.13512. Epub 2016 May 25. BJU Int. 2016. PMID: 27105017
Cited by
-
Evaluation of (123)I-orthoiodohippurate single kidney clearance rate by renal sequential scintigraphy in a large cohort of likely normal subjects aged between 0 and 18 years.Eur J Nucl Med Mol Imaging. 2006 Dec;33(12):1483-90. doi: 10.1007/s00259-006-0074-x. Epub 2006 Apr 28. Eur J Nucl Med Mol Imaging. 2006. PMID: 16645840
References
MeSH terms
Substances
LinkOut - more resources
Research Materials