Fractionation of carrier ampholytes in multicompartment electrolyzers with isoelectric membranes
- PMID: 8586068
- DOI: 10.1002/elps.11501601319
Fractionation of carrier ampholytes in multicompartment electrolyzers with isoelectric membranes
Abstract
Multicompartment electrolyzers with isoelectric membranes can be successfully utilized for the preparation of carrier ampholytes of narrow pH ranges from commercially available wider pH intervals. An example is given on the preparation of a 0.6 pH unit (pH 6.7-7.3) range from a standard pH 6-8 interval. A 10% Ampholine solution is focused in an electrolyzer equipped with the following isoelectric membranes: pI 6.0, 6.7, 7.3 and 8.0. The narrow pH 6.7-7.3 cut can be efficiently utilized for base-line separation and quantitation of hemoglobin A from its glycated form, Hb A1c. This analysis is important for the screening and follow up of diabetic patients. The advantage of multicompartment electrolyzers are: (i) precision in the preparation of narrow pH cuts, due to the presence of membranes with defined pI values; (ii) ability to perform in both small- and large-scale operations and (iii) absence of contaminants leaching from granulated supports, as typical of some previous techniques.
Similar articles
-
Qualitative and quantitative analysis of hemoglobin variants by capillary isoelectric focusing.J Chromatogr B Biomed Sci Appl. 1998 Feb 27;706(1):123-9. doi: 10.1016/s0378-4347(97)00444-1. J Chromatogr B Biomed Sci Appl. 1998. PMID: 9544814
-
Preparative isoelectric focusing in immobilized pH gradients. II. A case report.J Biochem Biophys Methods. 1983 Sep;8(2):157-72. doi: 10.1016/0165-022x(83)90041-6. J Biochem Biophys Methods. 1983. PMID: 6643921
-
Screening of umbilical cord blood hemoglobins by isoelectric focusing in capillaries.Electrophoresis. 1995 Aug;16(8):1485-91. doi: 10.1002/elps.11501601246. Electrophoresis. 1995. PMID: 8529619
-
Carrier ampholytes for IEF, on their fortieth anniversary (1967-2007), brought to trial in court: the verdict.Electrophoresis. 2007 Nov;28(21):3799-810. doi: 10.1002/elps.200700232. Electrophoresis. 2007. PMID: 17922506 Review.
-
Protein purification in multicompartment electrolyzers with isoelectric membranes.J Chromatogr B Biomed Sci Appl. 1997 Oct 10;699(1-2):105-15. doi: 10.1016/s0378-4347(97)00156-4. J Chromatogr B Biomed Sci Appl. 1997. PMID: 9392371 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous