Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate
- PMID: 8586082
- DOI: 10.1007/BF01791145
Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate
Abstract
. This investigation was undertaken in order to determine whether the clearance of technetium-99m mercaptoacetyltriglycine (99mTc-MAG3) is more closely correlated to the clearance of iodine-125 orthoiodohippurate (125I-OIH) than to the clearance of chromium-51 ethylene diamine tetra-acetate (51Cr-EDTA) and whether there is a clinically significant extrarenal clearance of 99mTc-MAG3 . Fifty-one patients with a glomerular filtration rate (GFR) of 4-132ml/min were studied. After a simultaneous single injection of the three tracers, plasma clearance was measured from blood samples 0-5h post injection (p.i.) (0-24h in patients with GFR<15ml/min). Renal plasma clearance was measured 0-5h p.i. The ratio between the renal plasma clearance of 99mTc-MAG3 and 125I-OIH was 0.57. The ratio between the renal plasma clearance of 99mTc-MAG3 and 51Cr-EDTA was 2.57. The coefficient of variation (CV) of the 99mTc-MAG3/125I-OIH ratio was significantly smaller than the CV of the 99mTc-MAG3/51Cr-EDTA ratio (13.4% versus 31.2%). The corresponding plasma clearance ratios were 0.59 (CV=14.8%) and 2.48 (CV=27.0%). Plasma clearance overestimated renal plasma clearance by 7.0ml/min (5.4%) for 99mTc-MAG3 and by 4.1ml/min (8.4%) for 51Cr-EDTA. The difference in plasma and renal plasma clearance of 125I-OIH of 5.5ml/min did not reach statistical significance. Red blood cell binding of 99mTc-MAG3, 125I-OIH and 51Cr-EDTA was 2.0%, 14.6% and 0.2%, respectively. Protein binding of 99mTc-MAG3, 125I-OIH and 51Cr-EDTA was 86.3%, 61.1% and 5.9%, respectively. The volume of distribution of 99mTc-MAG3, 125I-OIH and 51Cr-EDTA was 16.3%, 27.0% and 19.4% of body weight. In conclusion, the clearances of 99mTc-MAG3 and 125I-OIH are more closely correlated than is the clearance of 99mTc-MAG3 with GFR. Extrarenal clearance of 99mTc-MAG3 is relatively smaller than extrarenal clearance of 51Cr-EDTA. Thus, plasma clearance of 99mTc-MAG3 can be used as a measure of renal tubular function.
Similar articles
-
99mTc-MAG3 kinetics in the normal pig. A comparison to 131I-OIH and 125I-iothalamate after single injection and during continuous infusion.Clin Physiol. 1995 Jan;15(1):57-71. doi: 10.1111/j.1475-097x.1995.tb00430.x. Clin Physiol. 1995. PMID: 7712693
-
Clinical comparison of technetium-99m-EC, technetium-99m-MAG3 and iodine-131-OIH in renal disorders.J Nucl Med. 1995 Feb;36(2):224-8. J Nucl Med. 1995. PMID: 7830118
-
Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers.J Nucl Med. 1986 Jun;27(6):795-803. J Nucl Med. 1986. PMID: 2940350
-
Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.Semin Nucl Med. 1992 Apr;22(2):61-73. doi: 10.1016/s0001-2998(05)80082-0. Semin Nucl Med. 1992. PMID: 1534184 Review.
-
Technetium-99m-EC and other potential new agents in renal nuclear medicine.Semin Nucl Med. 1999 Apr;29(2):91-101. doi: 10.1016/s0001-2998(99)80002-6. Semin Nucl Med. 1999. PMID: 10321823 Review.
Cited by
-
Renal clearance estimated by rubidium-82 positron emission tomography/computed tomography and technetium-99m-mercaptoacetyltriglycine clearance infusion technique.Clin Physiol Funct Imaging. 2025 Mar;45(2):e70000. doi: 10.1111/cpf.70000. Clin Physiol Funct Imaging. 2025. PMID: 39988762 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources