Glomerular filtration rate in relation to extracellular fluid volume: similarity between 99mTc-DTPA and inulin
- PMID: 8586101
- DOI: 10.1007/BF01736989
Glomerular filtration rate in relation to extracellular fluid volume: similarity between 99mTc-DTPA and inulin
Abstract
The rate constant (alpha2) of the terminal exponential of the technetium-99m diethylene triamine penta-acetic acid (DTPA) plasma clearance curve is close to the ratio of glomerular filtration rate (GFR) to extracellular fluid volume (ECV) and is therefore a convenient, already normalised, measure of filtration function. Since alpha2 depends on the distribution volume of the tracer, our aim was to compare alpha2 from inulin and 99mTc-DTPA and also to compare the equilibration kinetics of the two filtration markers. Fifty millilitres of 99mTc-DTPA (250MBq) and inulin (10%), mixed in the same syringe, were given by intravenous injection in 15 patients undergoing routine 99mTc-DTPA renography for a variety of clinical indications. Frequent antecubital venous blood samples were taken up to about 4h after injection to construct plasma clearance curves from which GFR, ECV and GFR/ECV (i.e. the reciprocal of mean transit time through the distribution volume) were calculated. 99mTc-DTPA/inulin concentration ratio curves were also constructed after normalisation to the ratio in the syringe. GFR given by the two markers correlated closely (DTPA=0.98.inulin-0.4ml/min; r=0.98). 99mTc-DTPA had the same distribution volume as inulin, had a similar transit time through it and gave the same value of alpha2 (r=0.98). GFR/ECV from 99mTc-DTPA accordingly correlated closely with GFR/ECV from inulin (DTPA=0.75.inulin+0.99 ml/min; r=0.95). Even though the distribution volumes and the times to equilibration (i.e. to reach the terminal exponential) were similar, the distribution volume of 99mTc-DTPA at about 10min after injection was, after subtraction of the plasma volume, about twice that of inulin. We confirm the validity of 99mTc-DTPA for measuring GFR. alpha2 is a convenient measure of GFR, can be based on the terminal exponential of inulin of 99mTc-DTPA curves and can be converted to GFR/ECV with an appropriate scaling factor. The kinetics or the two clearance curves with respect to anatomical correlates of the exponentials and the rates of diffusion throughout the respective distribution volumes requires further study.
Similar articles
-
Measurement of the ratio of glomerular filtration rate to plasma volume from the technetium-99m diethylene triamine pentaacetic acid renogram: comparison with glomerular filtration rate in relation to extracellular fluid volume.Eur J Nucl Med. 1994 Apr;21(4):322-7. doi: 10.1007/BF00947967. Eur J Nucl Med. 1994. PMID: 8005156
-
Simultaneous measurement of extracellular fluid distribution and renal function with a single injection of 99mTc DTPA.Nephrol Dial Transplant. 1995 Oct;10(10):1829-33. Nephrol Dial Transplant. 1995. PMID: 8592589
-
Appropriate corrections to glomerular filtration rate and volume of distribution based on the bolus injection and single-compartment technique.Physiol Meas. 1999 Aug;20(3):313-27. doi: 10.1088/0967-3334/20/3/308. Physiol Meas. 1999. PMID: 10475584
-
Quantification of renal haemodynamics with radionuclides.Eur J Nucl Med. 1991;18(4):274-86. doi: 10.1007/BF00186653. Eur J Nucl Med. 1991. PMID: 2070806 Review.
-
The kinetic basis of glomerular filtration rate measurement and new concepts of indexation to body size.Eur J Nucl Med Mol Imaging. 2004 Jan;31(1):137-49. doi: 10.1007/s00259-003-1341-8. Epub 2003 Oct 31. Eur J Nucl Med Mol Imaging. 2004. PMID: 14593500 Review.
Cited by
-
Transcutaneous renal function monitor: precision during unsteady hemodynamics.J Clin Monit Comput. 1998 May;14(4):275-82. doi: 10.1023/a:1009992308204. J Clin Monit Comput. 1998. PMID: 9754617
-
Extracellular volume and glomerular filtration rate in children with chronic kidney disease.Clin J Am Soc Nephrol. 2011 Apr;6(4):741-7. doi: 10.2215/CJN.08020910. Epub 2011 Mar 24. Clin J Am Soc Nephrol. 2011. PMID: 21441126 Free PMC article.
-
Comparison between Two-sample Method with 99mTc-diethylenetriaminepentaacetic acid, Gates' Method and Estimated Glomerular Filtration Rate Values by Formula Based Methods in Healthy Kidney Donor Population.Indian J Nucl Med. 2017 Jul-Sep;32(3):188-193. doi: 10.4103/ijnm.IJNM_17_17. Indian J Nucl Med. 2017. PMID: 28680201 Free PMC article.
-
Measured Glomerular Filtration Rate: The Query for a Workable Golden Standard Technique.J Pers Med. 2021 Sep 24;11(10):949. doi: 10.3390/jpm11100949. J Pers Med. 2021. PMID: 34683089 Free PMC article. Review.
-
A comparison of different methods for the determination of glomerular filtration rate in elderly patients with chronic renal failure.Int Urol Nephrol. 2011 Mar;43(1):257-63. doi: 10.1007/s11255-010-9846-0. Epub 2010 Oct 20. Int Urol Nephrol. 2011. PMID: 20960232