Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1995 Dec;33(12):3138-45.
doi: 10.1128/jcm.33.12.3138-3145.1995.

Comparison of three staining methods for detecting microsporidia in fluids

Affiliations
Comparative Study

Comparison of three staining methods for detecting microsporidia in fluids

E S Didier et al. J Clin Microbiol. 1995 Dec.

Abstract

Calcofluor white 2MR, modified trichrome blue, and indirect immunofluorescent antibody (IFA) staining methods were evaluated and compared for detecting microsporidia in stool. Serial 10-fold dilutions of Encephalitozoon (Septata) intestinalis were prepared in three formalinized stool specimens or in Tris-buffered saline. Ten-microliter aliquots were smeared onto glass slides, fixed with methanol, stained, and read by at least three individuals. The results indicated that the calcofluor stain was the most sensitive method, required approximately 15 min to perform, but did generate some false-positive results due to similarly staining small yeast cells. The modified trichrome blue stain was nearly as sensitive as the calcofluor stain and allowed for easier distinction between microsporidia and yeast cells. This stain, however, required approximately 60 min to perform. The IFA stain with polyclonal murine antiserum against E. intestinalis was the least sensitive of the methods and required approximately 130 min to perform. The lower limit of detection with the calcofluor and modified trichrome stains was a concentration of about 500 organisms in 10 microliters of stool to detect one microsporidian after viewing 50 fields at a final magnification of x1,000. Reliability was also addressed by use of 74 stool, urine, and intestinal fluid specimens, 50 of which were confirmed for the presence of microsporidia by transmission electron microscopy (TEM). All TEM-positive specimens were detected by calcofluor and modified trichrome blue staining. Ten specimens were not detected by the IFA stain. An additional seven TEM-negative specimens were read positive for microsporidia with the calcofluor stain, and of these, five also were read positive with the modified trichrome blue stain. The resulting diagnostic paradigm was to screen specimens with the calcofluor stain and to confirm the results with the modified trichrome stain. IFA, which was less sensitive, may become useful for microsporidian species identification as specific antibodies become available.

PubMed Disclaimer

References

    1. J Parasitol. 1980 Aug;66(4):675-7 - PubMed
    1. J Clin Microbiol. 1995 Apr;33(4):805-10 - PubMed
    1. Rev Infect Dis. 1989 Mar-Apr;11(2):203-7 - PubMed
    1. J Infect Dis. 1991 Mar;163(3):617-21 - PubMed
    1. Parasitology. 1991 Feb;102 Pt 1:33-43 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources