PAR Corneal Topography System (PAR CTS): the clinical application of close-range photogrammetry
- PMID: 8587772
- DOI: 10.1097/00006324-199511000-00009
PAR Corneal Topography System (PAR CTS): the clinical application of close-range photogrammetry
Abstract
The PAR Corneal Topography System (CTS) is a computer-driven corneal imaging system which uses close-range photogrammetry (rasterphotogrammetry) to measure and produce a topographic map of the corneal surface. The PAR CTS makes direct point-by-point measurements of surface elevation using a stereo-triangulation technique. The CTS uses a grid pattern composed of horizontal and vertical lines spaced about 0.2 mm (200 microns) apart. Each grid intersection comprises a surface feature which can be located in multiple images and used to generate an (x,y,z) coordinate. Unlike placido disc-based videokeratoscopes, the PAR CTS requires neither a smooth reflective surface nor precise spatial alignment for accurate imaging. In addition to surface elevation, the PAR CTS computes axial and tangential curvatures and refractive power. Difference maps are available in all curvatures, refractive power, and in absolute elevation.
Similar articles
-
Intraoperative raster photogrammetry--the PAR Corneal Topography System.J Cataract Refract Surg. 1993;19 Suppl:188-92. J Cataract Refract Surg. 1993. PMID: 8450443
-
Accuracy of the PAR corneal topography system with spatial misalignment.CLAO J. 1993 Jan;19(1):64-8. doi: 10.1097/00140068-199301000-00012. CLAO J. 1993. PMID: 8453756
-
The PAR Technology Corneal Topography System.Refract Corneal Surg. 1992 Jan-Feb;8(1):88-96. Refract Corneal Surg. 1992. PMID: 1554645
-
Corneal topography.Curr Opin Ophthalmol. 1997 Aug;8(4):8-24. doi: 10.1097/00055735-199708000-00003. Curr Opin Ophthalmol. 1997. PMID: 10170448 Review.
-
[A review of mathematical descriptors of corneal asphericity].J Fr Ophtalmol. 2002 Jan;25(1):81-90. J Fr Ophtalmol. 2002. PMID: 11965125 Review. French.
Cited by
-
Using three-dimensional difference maps to assess changes in scoliotic deformities.Med Biol Eng Comput. 2002 May;40(3):290-5. doi: 10.1007/BF02344210. Med Biol Eng Comput. 2002. PMID: 12195975
-
Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.Br J Ophthalmol. 1999 Jul;83(7):774-8. doi: 10.1136/bjo.83.7.774. Br J Ophthalmol. 1999. PMID: 10381661 Free PMC article.
-
Stereo slit-scanning tomography of the anterior segment of the human eye.Sci Rep. 2024 Nov 10;14(1):27454. doi: 10.1038/s41598-024-78101-2. Sci Rep. 2024. PMID: 39523379 Free PMC article.
-
Biometric Measurement of Anterior Segment: A Review.Sensors (Basel). 2020 Jul 31;20(15):4285. doi: 10.3390/s20154285. Sensors (Basel). 2020. PMID: 32752014 Free PMC article. Review.
-
Wound healing anomalies after excimer laser photorefractive keratectomy: correlation of clinical outcomes, corneal topography, and confocal microscopy.Trans Am Ophthalmol Soc. 1997;95:629-714. Trans Am Ophthalmol Soc. 1997. PMID: 9440190 Free PMC article.