Cone-beam CT for radiotherapy applications
Abstract
Clinical implementation of cone-beam tomography has been hampered by the lack of two-dimensional electronic x-ray detectors that can encompass the full width of the body. We encountered the undersized detector problem in our development of a cone-beam CT system for radiotherapy applications. In order to mitigate the problem, we developed an algorithm which permits an increased reconstruction volume to be imaged using a detector of a given size. We describe the algorithm and report on its implementation using a radiotherapy simulator configured with a digital fluorography unit.
Similar articles
-
Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.Med Phys. 2003 Jul;30(7):1694-705. doi: 10.1118/1.1582470. Med Phys. 2003. PMID: 12906186
-
Chord-based image reconstruction in cone-beam CT with a curved detector.Med Phys. 2006 Oct;33(10):3743-57. doi: 10.1118/1.2337270. Med Phys. 2006. PMID: 17089840
-
Cone-beam volume CT breast imaging: feasibility study.Med Phys. 2002 May;29(5):755-70. doi: 10.1118/1.1461843. Med Phys. 2002. PMID: 12033572
-
X-ray computed microtomography (microCT) using synchrotron radiation (SR).Prog Biophys Mol Biol. 1996;65(1-2):133-69. doi: 10.1016/s0079-6107(96)00011-9. Prog Biophys Mol Biol. 1996. PMID: 9029944 Review. No abstract available.
-
Principles of computer assisted tomography (CAT) in radiographic and radioisotopic imaging.Phys Med Biol. 1976 Sep;21(5):689-732. doi: 10.1088/0031-9155/21/5/001. Phys Med Biol. 1976. PMID: 788005 Review. No abstract available.
Cited by
-
Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes.J Appl Clin Med Phys. 2009 Jan 27;10(1):33-42. doi: 10.1120/jacmp.v10i1.2852. J Appl Clin Med Phys. 2009. PMID: 19223832 Free PMC article.
-
Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.Phys Med Biol. 2013 Jan 21;58(2):205-30. doi: 10.1088/0031-9155/58/2/205. Epub 2012 Dec 21. Phys Med Biol. 2013. PMID: 23257068 Free PMC article.
-
History of Technological Advancements towards MR-Linac: The Future of Image-Guided Radiotherapy.J Clin Med. 2022 Aug 12;11(16):4730. doi: 10.3390/jcm11164730. J Clin Med. 2022. PMID: 36012969 Free PMC article. Review.
-
Generation and Evaluation of Synthetic Computed Tomography (CT) from Cone-Beam CT (CBCT) by Incorporating Feature-Driven Loss into Intensity-Based Loss Functions in Deep Convolutional Neural Network.Cancers (Basel). 2022 Sep 19;14(18):4534. doi: 10.3390/cancers14184534. Cancers (Basel). 2022. PMID: 36139692 Free PMC article.
-
Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.Med Phys. 2010 Oct;37(10):5456-70. doi: 10.1118/1.3488978. Med Phys. 2010. PMID: 21089782 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical