Comparison of defect size between thallium-201 and technetium-99m tetrofosmin myocardial single-photon emission computed tomography in patients with single-vessel coronary artery disease
- PMID: 8602561
- DOI: 10.1016/s0002-9149(97)89362-9
Comparison of defect size between thallium-201 and technetium-99m tetrofosmin myocardial single-photon emission computed tomography in patients with single-vessel coronary artery disease
Abstract
Defect size on exercise-rest technetium (Tc)-99m tetrofosmin myocardial perfusion imaging was compared with that on exercise-reinjection thallium-201 imaging with 20 patients with 1-vessel coronary artery disease. In each patient, exercise-reinjection thallium-201 single-photon emission computed tomography (SPECT) and exercise-rest Tc-99m tetrofosmin SPECT imaging were performed. For visual analysis of the obtained SPECT images, the left ventricular myocardium was divided into 20 segments based on 3 short-axis slices from the apical, middle, and basal ventricular levels. For quantitative analysis, a square region of interest was placed on the center of each segment which was used for visual analysis, and relative regional activity to the normal reference region was calculated for each segment. By visual interpretation of the images, exercise Tc-99m tetrofosmin imaging showed a smaller defect size than exercise thallium-201 imaging (6.9 +/- 3.9 vs 8.8 +/- 3.0 segments, p <0.01). In contrast, rest Tc-99m tetrofosmin imaging showed a defect size similar to that on reinjection thallium-201 imaging (5.9 +/- 3.6 vs 5.6 +/- 3.9 segments, p = NS). Similarly, the mean defect sizes during exercise determined by quantitative analysis were smaller on Tc-99m tetrofosmin SPECT than those on thallium-201 SPECT at all tested threshold cutoff points ranging from 50% to 70%, whereas there were no significant differences in defect sizes between rest Tc-99m tetrofosmin and reinjection thallium-201 imaging. These data indicate that exercise Tc-99m tetrofosmin SPECT defect size determined either by visual analysis or by quantitative analysis may be smaller than on exercise thallium-201 SPECT.
Similar articles
-
Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease.J Am Coll Cardiol. 1998 Feb;31(2):331-7. doi: 10.1016/s0735-1097(97)00484-1. J Am Coll Cardiol. 1998. PMID: 9462576
-
Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection.J Nucl Cardiol. 1999 May-Jun;6(3):270-7. doi: 10.1016/s1071-3581(99)90038-7. J Nucl Cardiol. 1999. PMID: 10385182
-
[Evaluation of myocardial viability using perfusion cardiac SPECT. 201-thallium rest/redistribution, 201-thallium rest/reinjection and technetium 99m tetrofosmin rest/postnitrates].Rev Esp Cardiol. 1998;51 Suppl 1:45-52. Rev Esp Cardiol. 1998. PMID: 9549398 Clinical Trial. Spanish.
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
-
Comparison of thallium-201 and technetium-99m methoxyisobutyl isonitrile.Am J Cardiol. 1992 Nov 5;70(14):30E-34E. doi: 10.1016/0002-9149(92)90036-x. Am J Cardiol. 1992. PMID: 1442570 Review.
Cited by
-
Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.J Nucl Cardiol. 2001 Jul-Aug;8(4):482-98. doi: 10.1067/mnc.2001.115078. J Nucl Cardiol. 2001. PMID: 11481571 Review. No abstract available.
-
The challenge of quantifying defect size and severity: reality versus algorithm.J Nucl Cardiol. 1999 May-Jun;6(3):362-71. doi: 10.1016/s1071-3581(99)90049-1. J Nucl Cardiol. 1999. PMID: 10385192 No abstract available.
-
Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis.J Nucl Cardiol. 2019 Aug;26(4):1269-1279. doi: 10.1007/s12350-018-1189-8. Epub 2018 Jan 29. J Nucl Cardiol. 2019. PMID: 29380286
-
Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT.J Nucl Cardiol. 2010 Jan-Feb;17(1):27-37. doi: 10.1007/s12350-009-9156-z. J Nucl Cardiol. 2010. PMID: 19936863 Free PMC article. Clinical Trial.
-
(99m)Tc-tetrofosmin as a prognostic agent?Eur J Nucl Med Mol Imaging. 2006 Jan;33(1):1-3. doi: 10.1007/s00259-005-1881-1. Eur J Nucl Med Mol Imaging. 2006. PMID: 16292581 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous