This study assessed the validity of cine magnetic resonance imaging (MRI) for measuring right and left ventricular volumes by using Simpson's rule in children with complex congenital heart disease. Forty-five patients with complex congenital heart disease (average age 2.6 years) and 10 controls (average age 2.3 years) were evaluated. The whole heart was encompassed by contiguous transverse sections. Ventricular volumes were calculated by adding luminal areas determined in each section at end diastole and end systole. End-diastolic and end-systolic volumes by MRI in both groups correlated well with those by ventriculography (r>0.89). Comparison of the ejection fraction in both ventricles in both groups yielded a good correlation between MRI and ventriculography (r>0.67). MRI technique in both groups had low intraobserver and interobserver variation (<6%). Cine MRI provides a suitable noninvasive means of quantifying ventricular volume in children with complex congenital heart disease.
Similar articles
-
A novel technique using biplane cine magnetic resonance imaging to evaluate left ventricular volume in children.Int J Card Imaging. 1999 Dec;15(6):465-71. doi: 10.1023/a:1006352217295. Int J Card Imaging. 1999. PMID: 10768741 Clinical Trial.
-
Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes.Korean J Radiol. 2018 Jul-Aug;19(4):704-714. doi: 10.3348/kjr.2018.19.4.704. Epub 2018 Jun 14. Korean J Radiol. 2018. PMID: 29962876 Free PMC article.
-
[Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoracic 3-dimensional echocardiography].Rofo. 2003 Jul;175(7):942-51. doi: 10.1055/s-2003-40435. Rofo. 2003. PMID: 12847649 German.
-
Congenital heart disease: measuring physiology with MRI.Semin Roentgenol. 1998 Jul;33(3):228-38. doi: 10.1016/s0037-198x(98)80005-9. Semin Roentgenol. 1998. PMID: 9682300 Review.
-
Cardiovascular Magnetic Resonance in Congenital Heart Disease: Focus on Heart Failure.Heart Fail Clin. 2021 Jan;17(1):157-165. doi: 10.1016/j.hfc.2020.08.012. Heart Fail Clin. 2021. PMID: 33220884 Review.
Cited by
-
Assessment of the normal adult right ventricular diastolic function using M-mode echocardiographic measurement of tricuspid ring motion.Int J Card Imaging. 1998 Dec;14(6):391-5. doi: 10.1023/a:1006127128984. Int J Card Imaging. 1998. PMID: 10453394
-
Measurements of left ventricular dimensions using real-time acquisition in cardiac magnetic resonance imaging: comparison with conventional gradient echo imaging.MAGMA. 2001 Oct;13(2):101-8. doi: 10.1007/BF02668158. MAGMA. 2001. PMID: 11502424
-
Cardiac catheterization is necessary before bidirectional Glenn and Fontan procedures in single ventricle physiology.Pediatr Cardiol. 2005 Mar-Apr;26(2):159-61. doi: 10.1007/s00246-004-0955-3. Pediatr Cardiol. 2005. PMID: 15868324 Review.
-
Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children.Pediatr Radiol. 2022 Jul;52(8):1462-1475. doi: 10.1007/s00247-022-05327-5. Epub 2022 Mar 30. Pediatr Radiol. 2022. PMID: 35353211 Free PMC article.
-
Artificial intelligence in pediatric and adult congenital cardiac MRI: an unmet clinical need.Cardiovasc Diagn Ther. 2019 Oct;9(Suppl 2):S310-S325. doi: 10.21037/cdt.2019.06.09. Cardiovasc Diagn Ther. 2019. PMID: 31737539 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical