Synthesis of a fluorescent analog of polychlorinated biphenyls for use in a continuous flow immunosensor assay
- PMID: 8608181
- DOI: 10.1021/bc00036a005
Synthesis of a fluorescent analog of polychlorinated biphenyls for use in a continuous flow immunosensor assay
Abstract
A synthetic scheme has been developed for the preparation of a dye-labeled analog of polychlorinated biphenyls. The reaction of 2,3,5-trichlorophenol with 3-bromopropylamine hydrobromide under basic conditions was used to introduce a free primary amine group into the parent compound by formation of a stable ether linkage. Reaction of this amine with the succinimidyl ester of a sulfoindocyanine dye resulted in amide bond formation to produce a fluorescently-labeled product. The dye conjugate was used to charge a column containing immobilized antibodies against polychlorinated biphenyls. Upon application of samples containing various concentrations of polychlorinated biphenyls, the fluorescent analog was displaced from the column in amounts proportional to the concentration of analyte. Concentrations of polychlorinated biphenyl as low as 1 ppm were measurable using this system.
Similar articles
-
Effect of lipid composition on phospholipase A2-catalyzed membrane leakage in immobilized liposomes: sensitization for polychlorinated biphenyls detection with antibody affinity column tandem with fluorescent liposome column.Electrophoresis. 2003 Sep;24(18):3165-71. doi: 10.1002/elps.200305530. Electrophoresis. 2003. PMID: 14518040
-
Reevaluation of polychlorinated biphenyl concentrations in milk and body fat of lactating cows.J Dairy Sci. 1990 Aug;73(8):2136-42. doi: 10.3168/jds.S0022-0302(90)78894-7. J Dairy Sci. 1990. PMID: 2121809
-
Detection of polychlorinated biphenyls using an antibody column in tandem with a fluorescent liposome column. Effect of albumin on phospholipase A2-catalyzed membrane leakage.J Chromatogr A. 2005 Sep 16;1087(1-2):229-35. doi: 10.1016/j.chroma.2005.03.013. J Chromatogr A. 2005. PMID: 16130718
-
Recent advances in the analysis of polychlorinated biphenyls in environmental and biological media.J Chromatogr. 1985 Nov 15;334(3):277-314. doi: 10.1016/s0021-9673(00)80273-3. J Chromatogr. 1985. PMID: 3935653 Review.
-
Methods for determining pesticides and polychlorinated biphenyls in food samples--problems and challenges.Crit Rev Food Sci Nutr. 2008 Nov;48(10):888-904. doi: 10.1080/10408390701761878. Crit Rev Food Sci Nutr. 2008. PMID: 18949592 Review.
Cited by
-
Immunoaffinity chromatography: an introduction to applications and recent developments.Bioanalysis. 2010 Apr;2(4):769-90. doi: 10.4155/bio.10.31. Bioanalysis. 2010. PMID: 20640220 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources