Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Apr;27(4):695-9.
doi: 10.1161/01.str.27.4.695.

Determination of duplex Doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial

Affiliations
Comparative Study

Determination of duplex Doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial

J P Carpenter et al. Stroke. 1996 Apr.

Abstract

Background and purpose: The North American Symptomatic Carotid Endarterectomy Trail (NASCET) demonstrated the benefit of carotid endarterectomy for symptomatic patients with > or = 70% carotid stenosis. Screening for detection of significant carotid occlusive disease has relied on duplex Doppler imaging. However, traditional duplex categories (50% to 79%, 80% to 99%) are not directly applicable to NASCET. We sought to evaluate duplex criteria for determination of > or = 70% carotid stenosis.

Methods: Duplex scan and arteriograms of 110 patients (210 carotids), performed within 1 month of each other, were reviewed by blinded readers. Arteriographic stenosis was determined by the NASCET method. Duplex measurements of peak systolic and end-diastolic velocity (PSV, EDV) were recorded, and ratios of velocities in the internal and common carotid arteries (ICA, CCA) were calculated. Receiver-operator characteristic (ROC) curves of sensitivity, specificity, positive and negative predictive values (PPV, NPV), and accuracy were determined.

Results: Interobserver agreement for measurement of arteriographic stenosis was "almost perfect" (kappa=0.86). The criteria chosen for detection of > or = 70% stenosis were PSVICA>210 cm/s (sensitivity, 94%; specificity, 77%; PPV, 68% NPV, 96% accuracy, 83%) EDVICA>70 cm/s (sensitivity, 92%; specificity, 60%; PPV, 73%; NPV, 86%; accuracy 77%), PSVica/PSVCCA >3.0 (sensitivity, 91%; specificity, 78%; PPV, 70%; NPV, 94%; accuracy, 83%), and EDVICA/EDVCCA>3.3 (sensitivity, 100%; specificity, 65%; PPV, 65% NPV, 100%; accuracy, 79%).

Conclusions: We conclude that > or = 70% carotid stenosis can be reliably determined by duplex Doppler ultrasound. Individual vascular laboratories must validate their own results.