. 1996 Mar;109(3):730-40.
doi: 10.1378/chest.109.3.730.

Electrocardiographic and electrophysiologic characteristics of anteroseptal, midseptal, and para-Hisian accessory pathways. Implication for radiofrequency catheter ablation

Affiliations

Electrocardiographic and electrophysiologic characteristics of anteroseptal, midseptal, and para-Hisian accessory pathways. Implication for radiofrequency catheter ablation

C T Tai et al. Chest. 1996 Mar.

Abstract

Study objective: To investigate the ECG characteristics, the electrophysiologic properties, and an effective radiofrequency catheter ablation technique in patients with septal accessory pathways.

Patients: Forty-six consecutive subjects with septal accessory pathways located in the anteroseptal, midseptal, and para-Hisian areas.

Design and interventions: ECGs obtained during sinus rhythm and orthodromic tachycardia, conduction properties obtained from electrophysiologic study, and results of two different ablation techniques were analyzed.

Measurements and results: (1) Twenty-four (52.2%) had manifest preexcitation and 15 (32.6%) had multiple accessory pathways; (2) midseptal pathways could be differentiated from anteroseptal and para-Hisian pathways by a negative delta wave in lead III and a biphasic delta wave in lead aVF during sinus rhythm, and a negative retrograde P wave in two inferior leads during orthodromic tachycardia; (2) midseptal pathways had better antegrade conduction properties and a significantly higher incidence (61.5%) of inducible atrial fibrillation; (4) radiofrequency catheter ablation using lower energy (20+/-6 W) had a comparable effect to ablation using higher energy (36+/-5 W), but without impairment of atrioventricular (AV) node conduction or development of AV block; and (5) during the follow-up period of 26+/-14 months (range, 5 to 54 months), three (6.5%) patients had recurrence.

Conclusions: Midseptal accessory pathways had ECG and electrophysiologic characteristics that were distinctive from those of anteroseptal and para-Hisian pathways. Catheter ablation of these septal pathways using low radiofrequency energy was safe and effective.