. 1977 Jul;41(1):58-67.
doi: 10.1161/01.res.41.1.58.

The canine heart as an electrocardiographic generator. Dependence on cardiac cell orientation

Free article

The canine heart as an electrocardiographic generator. Dependence on cardiac cell orientation

L V Corbin 2nd et al. Circ Res. 1977 Jul.
Free article

Abstract

Traditionally it is assumed that during cardiac depolarization the macroscopic current generators that produce electrocardiographic voltages can be represented as a uniform double-layer source, coincident with the macroscopic boundary between resting and depolarized cardiac fibers as measured with extracellular electrodes ("uniform" hypothesis). A segment of this boundary is thus considered as a current dipole oriented perpendicular to the boundary. We present evidence that, contrary to the above, the effective dipoles largely parallel the long axes of cardiac fibers ("axial" hypothesis). Calculated potentials in volume conductors differ markedly in the two cases. The magnitudes of rapid local "intrinsic" deflections also differ markedly. In our experiments, potential fields prodlced by stimulation at several cardiac sites and measured magnitudes of intrinsic deflections during normal depolarization and that caused by stimulation support the axial hypothesis and are incompatible with the uniform hypothesis. Our results suggest that axial orientation of sources is sufficiently strong so that predictions assuming the uniform hypothesis would be seriously in error, although the axial theory alone does not exactly describe all the measured potentials. Axial orientation of current generators must be considered in quantitative prediction of electrocardiographic potentials. tfurther study of the geometry of the intracellular depolarization boundary and its relation to fiber direction and to the frequency of lateral intercellular junctions is required to describe the generators exactly.

PubMed Disclaimer

Publication types

LinkOut - more resources