Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Apr;155(4):1407-9.

Common sheath reimplantation yields excellent results in the treatment of vesicoureteral reflux in duplicated collecting systems

Affiliations
  • PMID: 8632597

Common sheath reimplantation yields excellent results in the treatment of vesicoureteral reflux in duplicated collecting systems

P I Ellsworth et al. J Urol. 1996 Apr.

Abstract

Purpose: We evaluated our 10-year experience with the surgical treatment of vesicoureteral reflux in uncomplicated duplicated collecting systems.

Materials and methods: Between 1984 and 1994, 54 refluxing renal units (8 bilateral) in 37 female and 9 male patients required surgery. Patient age ranged from 7 months to 17 years (average 4.9 at surgery). Postoperative followup (average 14.2 months) included voiding cystourethrography and renal sonography or excretory urography.

Results: Common sheath ureteral reimplantation via an intravesical approach was performed in 48 of the 54 refluxing renal units. Of the remaining 6 renal units detrussorrhaphy was performed in 4, and ureteroureterostomy combined with ureteral reimplantation and partial lower pole nephrectomy were done in 1 each. Two treated renal units had persistent postoperative vesicoureteral reflux, which resolved after subureteral polytetrafluoroethylene (Teflon) injection. No renal had postoperative hydronephrosis. Contralateral reflux was identified in 1 patient who underwent unilateral reimplantation. Our overall success rate was 96% for the surgical correction of vesicoureteral reflux in uncomplicated duplicated collecting systems. Common sheath reimplantation had a 98% success rate.

Conclusions: Although a duplicated collecting system increases the risk for surgical treatment, the presence of a duplication anomaly does not adversely affect surgical outcome. Modifications of procedures commonly performed in the surgical treatment of single system reflux to accommodate common sheath reimplantation have excellent surgical results with minimal morbidity.

PubMed Disclaimer

LinkOut - more resources