Fluorescence flow analysis of lymphocyte activation using Hoechst 33342 dye
- PMID: 86569
- DOI: 10.1177/27.1.86569
Fluorescence flow analysis of lymphocyte activation using Hoechst 33342 dye
Abstract
The in vitro response of murine lymphocytes to allogeneic and mitogenic stimulation has been studied by using the nontoxic fluorescent DNA probe, Hoechst 33342, and a fluorescence flow cytometer-cell sorter. Under appropriate conditions, two peaks of fluorescent intensity, not related to cellular DNA content, can be seen. As early as 12 hr after culture set up, lymphocyte activation can be identified. It appears that Hoechst-labeled lymphocytes of higher fluorescence intensity represent those cells activated by allogeneic stimulation whereas cells obtained from the lower intensity peak are nonresponding lymphocytes.
Similar articles
-
Immunofluorescence of histone H1 in stimulated lymphocytes measured by flow cytophotometry.J Histochem Cytochem. 1979 Jan;27(1):417-25. doi: 10.1177/27.1.374604. J Histochem Cytochem. 1979. PMID: 374604
-
Different sensitivity of chromatin to acid denaturation in quiescent and cycling cells as revealed by flow cytometry.J Histochem Cytochem. 1979 Jan;27(1):478-85. doi: 10.1177/27.1.86572. J Histochem Cytochem. 1979. PMID: 86572
-
Simultaneous quantitation of Hoechst 33342 and immunofluorescence on viable cells using a fluorescence activated cell sorter.Cytometry. 1980 Sep;1(2):136-42. doi: 10.1002/cyto.990010208. Cytometry. 1980. PMID: 7028425
-
Chromatic shifts in the fluorescence emitted by murine thymocytes stained with Hoechst 33342.Cytometry A. 2004 Aug;60(2):173-81. doi: 10.1002/cyto.a.20058. Cytometry A. 2004. PMID: 15290718
-
Fluorescent probes to detect lymphocyte activation.Clin Exp Immunol. 1980 Jan;39(1):1-13. Clin Exp Immunol. 1980. PMID: 6156040 Free PMC article. Review.
Cited by
-
Karyological studies on established mosquito cell lines.Experientia. 1983 Jun 15;39(6):608-10. doi: 10.1007/BF01971121. Experientia. 1983. PMID: 6852197
-
Ultraviolet 320 nm laser excitation for flow cytometry.Cytometry A. 2017 Apr;91(4):314-325. doi: 10.1002/cyto.a.23066. Epub 2017 Feb 27. Cytometry A. 2017. PMID: 28240810 Free PMC article.
-
Breaking a Dogma: High-Throughput Live-Cell Imaging in Real-Time with Hoechst 33342.Adv Healthc Mater. 2023 Aug;12(20):e2300230. doi: 10.1002/adhm.202300230. Epub 2023 Mar 31. Adv Healthc Mater. 2023. PMID: 36934382 Free PMC article.
-
The DNA content of mouse two-cell embryos can be measured by microfluorimetric image analysis under conditions of cell viability.J Fluoresc. 1992 Sep;2(3):181-90. doi: 10.1007/BF00866933. J Fluoresc. 1992. PMID: 24241629
-
Hoechst 33342 dye uptake as a probe of membrane permeability changes in mammalian cells.Proc Natl Acad Sci U S A. 1981 Jan;78(1):363-7. doi: 10.1073/pnas.78.1.363. Proc Natl Acad Sci U S A. 1981. PMID: 6941251 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials