Conflicting prognostic results have been published as to the DNA variables, such as DNA ploidy, DNA index, and % S-phase cells for breast cancer patients. These variables can be obtained by interpreting DNA histograms by cell cycle analysis. Explanations for these conflicting results might be found on the level of the interpretation of the DNA histograms. In a previous study, the semi automated cell cycle analysis computer program MultiCycle (Phoenix Flow Systems, San Diego, CA) showed high intralaboratory reproducibility. However, what types of DNA histograms may cause disagreements was still unclear. The aim of this study was to determine the interlaboratory reproducibility of MultiCycle-based cell cycle analysis of 1,295 flow cytometric DNA histograms derived from fresh frozen breast cancer material and to clarify potential sources of interobserver variation when analyzing DNA histograms. DNA ploidy classification into diploid, hyperdiploid, tetraploid, hypertetraploid, and multiploid showed an interlaboratory agreement of 94% (kappa value = 0.92). The 6% discrepancies (n = 74) were caused by tetraploid peaks, as established in one laboratory, which shifted outside the tetraploid region on reanalysis by the other laboratory (37%), shoulders sometimes interpreted as peaks (24%), small peaks not always recognized as such (24%), fitting failures (10%), and overlooking of tetraploid peaks (5%). Furthermore, the cell cycle analysis variables showed variable reproducibility. The % S-phase cells of the first, second, and third cell cycle showed overall a moderate reproducibility (0.62 < or = R < or = 0.79), but the average % S-phase cells and the average aneuploid % S-phase cells were more reproducible with correlation coefficients of 0.89 and 0.81, respectively. The coefficient of variation of the G0/G1 peak of the first cell cycle, the DNA indices and the % diploid cells were highly reproducible (R > or = 0.94), and the % G2/M-phase cells of the first, second, and third cell cycle were poorly reproducible (0.22 < or = R < or = 0.68). When a cut-point was used at the mean value of 7% for the average % S-phase cells, the number of "threshold discrepancy cases" was 6%. Sources of variation for cell cycle analysis were variations in the debris correction procedures, disagreement about the modes of the aneuploid peaks, disagreement about small peaks, shoulders sometimes interpreted as peaks, and overlooking of tetraploid peaks.
Comment in
-
Interlaboratory reproducibility of the interpretation of flow cytometric DNA histograms.Hum Pathol. 1997 Feb;28(2):257-8. doi: 10.1016/s0046-8177(97)90118-0. Hum Pathol. 1997. PMID: 9023414 No abstract available.
Similar articles
-
Reproducibility of semi-automated cell cycle analysis of flow cytometric DNA-histograms of fresh breast cancer material.Anal Cell Pathol. 1995 Jan;8(1):1-13. Anal Cell Pathol. 1995. PMID: 7734408
-
Comparison of five cell cycle analysis models applied to 1414 flow cytometric DNA histograms of fresh frozen breast cancer.Cytometry. 1997 Feb 15;30(1):54-60. Cytometry. 1997. PMID: 9056743
-
Prognostic implications of different cell cycle analysis models of flow cytometric DNA histograms of 1,301 breast cancer patients: results from the Multicenter Morphometric Mammary Carcinoma Project (MMMCP).Int J Cancer. 1997 Jun 20;74(3):260-9. doi: 10.1002/(sici)1097-0215(19970620)74:3<260::aid-ijc5>3.0.co;2-x. Int J Cancer. 1997. PMID: 9221802
-
Flow cytometric DNA analysis of human solid tumors: a review of the interpretation of DNA histograms.Hum Pathol. 1991 Nov;22(11):1085-98. doi: 10.1016/0046-8177(91)90260-v. Hum Pathol. 1991. PMID: 1743692 Review.
-
[Flow cytometric analysis of DNA ploidy pattern in breast cancer: malignant potential and prognostic implication].Nihon Rinsho. 1992 Oct;50(10):2444-9. Nihon Rinsho. 1992. PMID: 1447815 Review. Japanese.
Cited by
-
Short-term significance of DNA ploidy and cell proliferation in breast carcinoma: a multivariate analysis of prognostic markers in a series of 308 patients.J Clin Pathol. 1999 Aug;52(8):604-11. doi: 10.1136/jcp.52.8.604. J Clin Pathol. 1999. PMID: 10645231 Free PMC article.
-
Prognostic relevance of DNA flow cytometry in breast cancer revisited: The 25-year experience of the Portuguese Institute of Oncology of Lisbon.Oncol Lett. 2017 Apr;13(4):2027-2033. doi: 10.3892/ol.2017.5718. Epub 2017 Feb 13. Oncol Lett. 2017. PMID: 28454358 Free PMC article.
-
Assessment of Chromosomal Aberrations and S-phase Fraction in Patients With Esophageal Cancer.Cureus. 2025 May 15;17(5):e84204. doi: 10.7759/cureus.84204. eCollection 2025 May. Cureus. 2025. PMID: 40519486 Free PMC article.
-
Deciphering a subgroup of breast carcinomas with putative progression of grade during carcinogenesis revealed by comparative genomic hybridisation (CGH) and immunohistochemistry.Br J Cancer. 2004 Apr 5;90(7):1422-8. doi: 10.1038/sj.bjc.6601658. Br J Cancer. 2004. PMID: 15054466 Free PMC article.
-
Tumour heterogeneity of DNA cell cycle variables in breast cancer measured by flow cytometry.J Clin Pathol. 1996 Nov;49(11):931-7. doi: 10.1136/jcp.49.11.931. J Clin Pathol. 1996. PMID: 8944615 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical