Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Jun 15;61(11):1624-9.
doi: 10.1097/00007890-199606150-00013.

Plasma prostaglandin E1 concentrations and hemodynamics during intravenous infusions of prostaglandin E1 in humans and swine

Affiliations

Plasma prostaglandin E1 concentrations and hemodynamics during intravenous infusions of prostaglandin E1 in humans and swine

J A Awas et al. Transplantation. .

Abstract

Prostaglandin (PG) E1 administered intravenously has been used for the treatment of primary nonfunction of hepatic allografts and fulminant hepatic failure. It has been proposed that this therapy may improve hepatic blood flow via the vasodilating properties of PGE1. However, PGE1 undergoes extensive metabolic inactivation by the lung and the concentration of PGE1 reaching the liver during intravenous administration has not been determined. Thus, we measured plasma PGE1 concentrations in patients with hepatic dysfunction being treated with PGE1 and in a swine model of PGE1 infusion. We also determined the hemodynamic effects of PGE1 infusion in swine. Blood was sampled from the pulmonary artery, carotid artery, portal vein, and hepatic vein in swine infused with PGE1 (range, 0.67-4.9 microg/kg/hr) demonstrating: (1) a pulmonary extraction ratio of PGE1 of 0.78 +/- 0.12, (2) a splanchnic extraction ratio of PGE1 of 0.54 +/- 0.23, and (3) levels of PGE1 in the systemic circulation of </= 78 pg/ml, even at the highest infusion rates. Despite significant increases in body temperature and pulse rate, hepatic hemodynamics were not affected by the PGE1 infusions in healthy swine. Seven patients receiving intravenous PGE1 for hepatic dysfunction (0.11-1.30 microg/kg/hr) had a pulmonary extraction ratio of 0.69 +/- 0.17. Systemic arterial concentrations of PGE1 were </= 62 pg/ml. These results suggest that due to clearance of PGE2 in the pulmonary and splanchnic circulations, current clinical protocols for intravenous administration of PGE1 are not likely to affect perihepatic hemodynamics.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources