Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 May;53(5):328-33.
doi: 10.1136/oem.53.5.328.

Biomarkers of exposure to low concentrations of benzene: a field assessment

Affiliations

Biomarkers of exposure to low concentrations of benzene: a field assessment

C N Ong et al. Occup Environ Med. 1996 May.

Abstract

Objective: To carry out a comprehensive field investigation to evaluate various conventional and recently developed biomarkers for exposure to low concentrations of benzene.

Methods: Analyses were carried out on environmental air, unmetabolised benzene in blood and urine, urinary trans, transmuconic acid, and three major phenolic metabolites of benzene: phenol, catechol, and hydroquinone. Validations of these biomarkers were performed on 131 never smokers occupationally exposed to the time weighed average benzene concentration of 0.25 ppm (range, 0.01 to 3.5 ppm).

Results: Among the six biomarkers studied, unmetabolised benzene in urine correlated best with environmental benzene concentration (correlation coefficient, r = 0.76), followed by benzene in blood (r = 0.64). When urinary metabolites were compared with environmental benzene, trans, trans-muconic acid showed a close correlation (r = 0.53) followed by hydroquinone (r = 0.44), and to a lesser extent with urinary phenol (r = 0.38). No correlation was found between catechol and environmental benzene concentrations. Although unmetabolised benzene in urine correlates best with benzene exposure, owing to serious technical drawbacks, its use is limited. Among the metabolites, trans, trans-muconic acid seems to be more reliable than other phenolic compounds. Nevertheless, detailed analyses failed to show that it is specific for monitoring benzene exposures below 0.25 ppm.

Conclusion: The overall results suggest that most of the currently available biomarkers are unable to provide sufficient specificity for monitoring of low concentrations of benzene exposure. If a lower occupational exposure limit for benzene is to be considered, the reliability of the biomarker and the technical limitations of measurements have to be carefully validated.

PubMed Disclaimer

Comment in

References

    1. Am Ind Hyg Assoc J. 1987 Sep;48(9):786-90 - PubMed
    1. Occup Environ Med. 1995 Sep;52(9):611-20 - PubMed
    1. Br J Ind Med. 1988 Jul;45(7):487-92 - PubMed
    1. Br J Ind Med. 1989 Feb;46(2):122-7 - PubMed
    1. Environ Health Perspect. 1989 Jul;82:189-91 - PubMed

Publication types