Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Jul 1;56(13):3055-61.

Minibody: A novel engineered anti-carcinoembryonic antigen antibody fragment (single-chain Fv-CH3) which exhibits rapid, high-level targeting of xenografts

Affiliations
  • PMID: 8674062
Comparative Study

Minibody: A novel engineered anti-carcinoembryonic antigen antibody fragment (single-chain Fv-CH3) which exhibits rapid, high-level targeting of xenografts

S Hu et al. Cancer Res. .

Abstract

A novel engineered antibody fragment (VL-VH-CH3, or "minibody") with bivalent binding to carcinoembryonic antigen (CEA) was produced by genetic fusion of a T84.66 (anti-CEA) single-chain antibody (scFv) to the human IgG1 CH3 domain. Two designs for the connecting peptide were evaluated. In the T84.66/212 LD minibody, a two-amino acid linker (generated by fusion of restriction sites) was used to join VH and CH3. In the T84.66/212 Flex minibody, the human IgG1 hinge plus an additional 10 residues were used as the connecting peptide. Size exclusion chromatography of purified minibodies demonstrated that both proteins had assembled into Mr80,000 dimers as expected. Furthermore, analysis by SDS-PAGE under nonreducing conditions was consistent with disulfide bond formation in the hinge of the T84.66 Flex minibody. Purified minibodies retained high affinity for CEA (KA, 2 x 10(9) M(-1)) and demonstrated bivalent binding to antigen. Tumor targeting properties were evaluated in vivo using athymic mice bearing LS174T human colon carcinoma xenografts. 123I-labeled T84.66 minibodies demonstrated rapid, high tumor uptake, reaching 17% injected dose/gram (%ID/g) for the LD minibody and 33%ID/g for the Flex minibody at 6 h following injection. Radioiodinated minibody also cleared rapidly from the circulation, yielding high tumor:blood uptake ratios: 44.5 at 24 h for the LD minibody and 64.9 at 48 h for the Flex minibody. Rapid localization by the T84.66/212 Flex minibody allowed imaging of xenografts at 4 and 19 h after administration.

PubMed Disclaimer

Publication types

LinkOut - more resources