Variability of expert observers in evaluating the optic disc
- PMID: 867638
- PMCID: PMC1311528
Variability of expert observers in evaluating the optic disc
Abstract
A significant amount of variability exists between observers in designating cup/diac (C/D) ratios. Further, different methods are used for evaluating the size of the cup. On method uses a combination of contour and color, the other specifically measures contour and pallor separately. This study confirms that these methods yeild different numerical results. Interestingly, the "cupping/pallor" observers show no significant difference among one another in C/D determination which may support the notion that cupping observations are more consistent than "standard" C/D ratios. Though both groups feel the cup is larger on stereo compared to monocular viewing, the "cupping/pallor" group demonstrated much greater differences in this regard. However, the evaluation of pallor by the latter group corresponded closely to the C/D ratios of the "standard" group both for nonstereo and stereo. An individual observer is reasonably consistent on repeat evaluation, but at times, inconsistency is quite substantial. These inconsistencies lead to the conclusion that C/D ratios are an inexact method of recording the status of a disc. Except for considerable changes over time, this numerical method is probably not reliable in checking for small disc changes. However, the disc alone can provide clues as to whether it is physiologic or pathologic. Nevertheless, even with expert observers, significant variability exists in interpretation of an optic disc in this regard. Individuals who evaluate the disc cup by cupping and pallor tend to call discs more pathologic than other observers. The clinical implications of this study suggest that certain observers are more accurate than others and certain discs are more easily evaluated than others. Yet, no one method seems foolproof and no specific criteria can as yet distinguish a normal from an abnormal disc. Stereo color transparencies are evaluated more accurately than are nonstereo color prints. Vessel detail and pallor patterns are probably the most useful disc characteristics to observe. In this regard, a C/D ratio does nothing to indicate whether a disc is normal or not. A statement as to the observer's opinion should be made for each disc evaluation in addition to recording the appearance of the disc.
Similar articles
-
Agreement in assessing glaucomatous discs in a clinical teaching setting with stereoscopic disc photographs, planimetry, and laser scanning tomography.J Glaucoma. 1999 Apr;8(2):99-104. J Glaucoma. 1999. PMID: 10209725
-
Observer variability in optic disc assessment: implications for glaucoma shared care.Ophthalmic Physiol Opt. 2000 Jul;20(4):265-73. Ophthalmic Physiol Opt. 2000. PMID: 10962691
-
Variance owing to observer, repeat imaging, and fundus camera type on cup-to-disc ratio estimates by stereo planimetry.J Glaucoma. 2009 Apr-May;18(4):305-10. doi: 10.1097/IJG.0b013e318181545e. J Glaucoma. 2009. PMID: 19365196
-
Pathological optic-disc cupping.Curr Opin Ophthalmol. 2006 Feb;17(1):1-6. doi: 10.1097/01.icu.0000193072.17122.f3. Curr Opin Ophthalmol. 2006. PMID: 16436917 Review.
-
Optic nerve cupping and the neuro-ophthalmologist.J Neuroophthalmol. 2013 Dec;33(4):377-89. doi: 10.1097/WON.0000000000000080. J Neuroophthalmol. 2013. PMID: 24256877 Review.
Cited by
-
Use of sequential Heidelberg retina tomograph images to identify changes at the optic disc in ocular hypertensive patients at risk of developing glaucoma.Br J Ophthalmol. 2000 Sep;84(9):993-8. doi: 10.1136/bjo.84.9.993. Br J Ophthalmol. 2000. PMID: 10966952 Free PMC article.
-
The effect of photographic light brightness on cup to disc ratio grading.BMC Ophthalmol. 2021 Dec 13;21(1):431. doi: 10.1186/s12886-021-02209-6. BMC Ophthalmol. 2021. PMID: 34903194 Free PMC article.
-
Effect of retinal nerve fibre loss on the optic nerve head configuration in early glaucoma.Graefes Arch Clin Exp Ophthalmol. 1983;220(4):193-6. doi: 10.1007/BF02186668. Graefes Arch Clin Exp Ophthalmol. 1983. PMID: 6884783
-
Laser scanning tomography and stereophotogrammetry in three-dimensional optic disc analysis.Graefes Arch Clin Exp Ophthalmol. 1993 Apr;231(4):193-8. doi: 10.1007/BF00918840. Graefes Arch Clin Exp Ophthalmol. 1993. PMID: 8486299
-
Convex Representations Using Deep Archetypal Analysis for Predicting Glaucoma.IEEE J Transl Eng Health Med. 2020 May 28;8:3800107. doi: 10.1109/JTEHM.2020.2982150. eCollection 2020. IEEE J Transl Eng Health Med. 2020. PMID: 32596065 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous