Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1996 Jun;76(6):795-801.
doi: 10.1093/bja/76.6.795.

Remifentanil reduces auditory and somatosensory evoked responses during isoflurane anaesthesia in a dose-dependent manner

Affiliations
Free article
Clinical Trial

Remifentanil reduces auditory and somatosensory evoked responses during isoflurane anaesthesia in a dose-dependent manner

I Crabb et al. Br J Anaesth. 1996 Jun.
Free article

Abstract

We studied 60 patients during stable isoflurane anaesthesia (0.4 MAC) after premedication with temazepam. Patients were allocated randomly to one of three dose regimens of remifentanil: 1 microgram kg-1 i.v. over 1 min and an infusion of 0.2 microgram kg-1 min-1 (low dose); 2.5 micrograms kg-1 and 0.5 microgram kg-1 min-1 (medium dose); and 5 micrograms kg-1 and 1 microgram kg-1 min-1 (high dose). The auditory (AER) and median nerve somatosensory (SER) responses were elicited throughout, and recorded before and after tracheal intubation, and surgical incision, together with systolic and diastolic arterial pressure and heart rate. Venous blood concentrations of remifentanil were measured at the above times. After administration of remifentanil, Pa and Nb amplitudes of the AER increased at the low dose, remained constant at the medium dose and decreased at the high dose. This dose-related effect was linear and significant (P = 0.012, P = 0.05). Pa amplitude correlated inversely with remifentanil blood concentrations before and after intubation and incision (P = 0.002, P < 0.001, P < 0.001 and P < 0.001). In the SER, P15-N20 amplitudes decreased after administration of remifentanil (P < 0.001), whereas P25-N35 and N35-P45 amplitudes increased at all dose concentrations (P < 0.001 and P < 0.001). After intubation, P15-N20 and N35-P45 amplitudes increased at the low dose, did not change at the medium dose and decreased at the high dose (P = 0.001, P = 0.027). After remifentanil, systolic and diastolic arterial pressure and heart rate decreased in a linearly dose-related manner (P = 0.033, P < 0.001, P < 0.001). At all doses the three variables increased after intubation (P = 0.001, P < 0.001, P < 0.01), and systolic and diastolic arterial pressure increased after incision (P = 0.027, P = 0.039).