Comparison of capillary electrophoretic and liquid chromatographic determination of hypoxanthine and xanthine for the diagnosis of xanthinuria
- PMID: 8680593
- DOI: 10.1016/0021-9673(95)01086-6
Comparison of capillary electrophoretic and liquid chromatographic determination of hypoxanthine and xanthine for the diagnosis of xanthinuria
Abstract
A capillary electrophoretic (CE) method for the determination of hypoxanthine and xanthine in urine was developed to diagnose xanthinuria. The linearity was excellent up to 200 mumol l-1 for the two compounds and the limit of quantitation was 2 mumol l-1. A comparison o the results obtained using CE was made with those obtained by the high-performance liquid chromatographic (HPLC) technique described previously. With regard to specificity, sensitivity and reproducibility, the results are similar but CE is more rapid than HPLC.