Technetium-99m-methoxyisobutylisonitrile in localization of ectopic parathyroid adenoma
- PMID: 8691254
Technetium-99m-methoxyisobutylisonitrile in localization of ectopic parathyroid adenoma
Abstract
Preoperative localization of ectopic parathyroid lesions is crucial for the correct treatment of patients with primary hyperparathyroidism. Invasive and noninvasive procedures, including selective venography, ultrasound, CT and MRI provide limited sensitivity in the detection of ectopic lesions. We report three patients in whom 99mTc-MIBI scintigraphy accurately detected ectopic parathyroid adenomas and was instrumental in the cure for these patients. Technetium-99m-MIBI scintigraphy provides a simple and accurate noninvasive test for the detection of ectopic parathyroid adenomas.
Similar articles
-
Double-phase Tc-99m sestamibi scintigraphy in the preoperative location of lesions causing hyperparathyroidism.Clin Nucl Med. 1998 May;23(5):291-7. doi: 10.1097/00003072-199805000-00005. Clin Nucl Med. 1998. PMID: 9596153
-
Localization of an ectopic parathyroid adenoma by double-phase technetium-99m-sestamibi scintigraphy.J Nucl Med. 1995 Oct;36(10):1840-2. J Nucl Med. 1995. PMID: 7562052
-
Technetium-99m-sestamibi SPECT localization of mediastinal parathyroid adenoma.J Nucl Med. 1996 Sep;37(9):1535-7. J Nucl Med. 1996. PMID: 8790213
-
[99m Tc-sestamibi in the diagnosis of the location of hyperparathyroidism].Rev Esp Med Nucl. 1998;17(2):102-11. Rev Esp Med Nucl. 1998. PMID: 9611280 Review. Spanish. No abstract available.
-
Technetium-99m tetrofosmin parathyroid imaging in patients with primary hyperparathyroidism.Intern Med. 2000 Feb;39(2):101-6. doi: 10.2169/internalmedicine.39.101. Intern Med. 2000. PMID: 10732824 Review.
Cited by
-
The efficacy of technetium-99m-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glands.Surg Today. 1999;29(4):307-12. doi: 10.1007/BF02483053. Surg Today. 1999. PMID: 10211559
-
Ectopic thymic parathyroid adenoma.BMJ Case Rep. 2014 Sep 25;2014:bcr2014206634. doi: 10.1136/bcr-2014-206634. BMJ Case Rep. 2014. PMID: 25257890 Free PMC article. No abstract available.
-
(11)C-Methionine positron emission tomography-computed tomography in localization of methoxyisobutyl isonitrile negative ectopic parathyroid adenoma.Indian J Nucl Med. 2016 Jan-Mar;31(1):49-51. doi: 10.4103/0972-3919.172362. Indian J Nucl Med. 2016. PMID: 26917896 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources