Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Jul;112(1):111-6.
doi: 10.1016/s0022-5223(96)70184-8.

Euro-Collins solution exacerbates lung injury in the setting of high-flow reperfusion

Affiliations
Free article

Euro-Collins solution exacerbates lung injury in the setting of high-flow reperfusion

N F DeLima et al. J Thorac Cardiovasc Surg. 1996 Jul.
Free article

Abstract

Single-lung transplantation has been abandoned for the treatment of pulmonary hypertension by many centers because of overperfusion of the graft following implantation. Euro-Collins solution is currently used for lung preservation despite the vasoconstrictive effect of this intracellular-type solution. We hypothesized that high-flow reperfusion, alone or in combination with Euro-Collins-induced vasoconstriction, may cause lung dysfunction. Twenty-eight New Zealand White rabbit lungs were harvested and studied in an isolated, blood-perfused model of lung function after 4 hours of cold ischemia. Control lungs were preserved with 50 ml/kg cold saline solution flush and reperfused at either normal flow (60 ml/min) or high flow (120 ml/min). Experimental lungs were preserved with 50 ml/kg cold Euro-Collins solution and reperfused at normal or high flow rates. The arteriovenous oxygen gradient at the end of the 30-minute reperfusion period was significantly lower in the high-flow versus the low-flow experimental group (31.1 +/- 4.2 vs 130.6 +/- 41.6 mm Hg, p < 0.05). The pulmonary vascular resistance was increased in the high-flow groups and the experimental groups, with a statistically significant difference between low-flow experimental and control groups (64374.4 +/- 5722.6 vs 37041.5 +/- 2110.9 dynes x sec x cm(-5), p < 0.001). The percentage decrease in dynamic airway compliance in the high-flow experimental group was markedly different from that in the high-flow control group (-51% +/- 13.3% vs -10.15% +/- 3.4%, p < 0.05). Similarly, the wet/dry ratio of the lungs in the high-flow experimental group (13.92 +/- 2.32) was significantly greater than that in the low-flow experimental group (6.27 +/- 0.19, p < 0.01) and than that in the high-flow control group (5.88 +/- 0.23, p < 0.001). These data demonstrate that high-flow reperfusion and preservation with Euro-Collins solution are deleterious to lung function, both individually and in combination, in an ex vivo rabbit lung model. Lung preservation with Euro-Collins solution may not be optimal when high-flow reperfusion is anticipated, as in the setting of unilateral lung transplantation for pulmonary hypertension.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources