Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Guideline
. 1995 Dec;17(4):301-10.

Guide-lines for near patient testing: haematology

Collaborators, Affiliations
  • PMID: 8697724
Guideline

Guide-lines for near patient testing: haematology

Near Patient Testing Working Party et al. Clin Lab Haematol. 1995 Dec.

Abstract

These guide-lines provide a framework for the local arrangement of near patient testing (NPT) services for haematology tests. The guidance may be applied to medical and surgical units within hospitals (e.g. ITU, renal dialysis units, casualty) as well as general practitioners' surgeries, for blood counts and coagulation testing. The professional head of the central laboratory must take responsibility for all aspects of the NPT service, although there should be full discussion with the clinical departments involved and joint ownership of the results. NPT operators must be trained and accredited by the central laboratory. Equipment selected should normally have received a satisfactory evaluation report from the Medical Devices Agency (MDA), and should generate results that are comparable with those of the central laboratory. If a full MDA operation evaluation has not been performed, the purchaser should perform a local assessment according to the protocol in this document. The suitability of the equipment, imprecision, and comparability must be studied. The NPT equipment must be properly maintained and calibrated, and a record of patient identity, date and time of testing, reagent lot numbers, and operator must be kept. The central laboratory must participate in a suitable external quality assessment programme (EQA), and provide systems for EQA and internal quality control (IQC) of the NPT site.

PubMed Disclaimer

LinkOut - more resources