Tracer kinetic modelling of receptor data with mathematical metabolite correction
- PMID: 8698059
- DOI: 10.1007/BF00833389
Tracer kinetic modelling of receptor data with mathematical metabolite correction
Abstract
Quantitation of metabolic processes with dynamic positron emission tomography (PET) and tracer kinetic modelling relies on the time course of authentic ligand in plasma, i.e. the input curve. The determination of the latter often requires the measurement of labelled metabolites, a laborious procedure. In this study we examined the possibility of mathematical metabolite correction, which might obviate the need for actual metabolite measurements. Mathematical metabolite correction was implemented by estimating the input curve together with kinetic tissue parameters. The general feasibility of the approach was evaluated in a Monte Carlo simulation using a two tissue compartment model. The method was then applied to a series of five human carbon-11 iomazenil PET studies. The measured cerebral tissue time-activity curves were fitted with a single tissue compartment model. For mathematical metabolite correction the input curve following the peak was approximated by a sum of three decaying exponentials, the amplitudes and characteristic half-times of which were then estimated by the fitting routine. In the simulation study the parameters used to generate synthetic tissue time-activity curves (K1-k4) were refitted with reasonable identifiability when using mathematical metabolite correction. Absolute quantitation of distribution volumes was found to be possible provided that the metabolite and the kinetic models are adequate. If the kinetic model is oversimplified, the linearity of the correlation between true and estimated distribution volumes is still maintained, although the linear regression becomes dependent on the input curve. These simulation results were confirmed when applying mathematical metabolite correction to the [11C]iomazenil study. Estimates of the distribution volume calculated with a measured input curve were linearly related to the estimates calculated using mathematical metabolite correction with correlation coefficients >0.990. However, the slope of the regression line displayed considerable variability among the subjects (0.33-0.95), demonstrating that absolute quantitation of the distribution volume was impaired. Mathematical metabolite correction is a feasible method and may prove useful in cases where actual metabolite data cannot be obtained. The potential for absolute quantitation seems limited, but the method allows the quantitative assessment of regional ratios of receptor measures.
Similar articles
-
[11C]flumazenil metabolite measurement in plasma is not necessary for accurate brain benzodiazepine receptor quantification.Eur J Nucl Med. 2000 Nov;27(11):1674-83. doi: 10.1007/s002590000336. Eur J Nucl Med. 2000. PMID: 11105824
-
Modeling alternatives for cerebral carbon-11-iomazenil kinetics.J Nucl Med. 1996 Apr;37(4):699-705. J Nucl Med. 1996. PMID: 8691270
-
Similarity and robustness of PET and SPECT binding parameters for benzodiazepine receptors.J Cereb Blood Flow Metab. 2000 Nov;20(11):1587-603. doi: 10.1097/00004647-200011000-00009. J Cereb Blood Flow Metab. 2000. PMID: 11083234
-
Imaging neurochemistry of cerebrovascular disease with PET and SPECT.Q J Nucl Med. 1998 Sep;42(3):193-8. Q J Nucl Med. 1998. PMID: 9796367 Review.
-
Radioligand studies: imaging and quantitative analysis.Eur Neuropsychopharmacol. 2002 Dec;12(6):513-6. doi: 10.1016/s0924-977x(02)00100-1. Eur Neuropsychopharmacol. 2002. PMID: 12468014 Review.
Cited by
-
Plasma radiometabolite correction in dynamic PET studies: Insights on the available modeling approaches.J Cereb Blood Flow Metab. 2016 Feb;36(2):326-39. doi: 10.1177/0271678X15610585. Epub 2015 Oct 14. J Cereb Blood Flow Metab. 2016. PMID: 26661202 Free PMC article. Review.
-
Determination of the Input Function at the Entry of the Tissue of Interest and Its Impact on PET Kinetic Modeling Parameters.Mol Imaging Biol. 2015 Dec;17(6):748-56. doi: 10.1007/s11307-015-0895-8. Mol Imaging Biol. 2015. PMID: 26395903 Review.
-
Simultaneous radiomethylation of [11C]harmine and [11C]DASB and kinetic modeling approach for serotonergic brain imaging in the same individual.Sci Rep. 2022 Feb 28;12(1):3283. doi: 10.1038/s41598-022-06906-0. Sci Rep. 2022. PMID: 35228586 Free PMC article.
-
Total-Body PET Kinetic Modeling and Potential Opportunities Using Deep Learning.PET Clin. 2021 Oct;16(4):613-625. doi: 10.1016/j.cpet.2021.06.009. Epub 2021 Aug 3. PET Clin. 2021. PMID: 34353745 Free PMC article. Review.
-
Advances in PET/MR instrumentation and image reconstruction.Br J Radiol. 2018 Jan;91(1081):20160363. doi: 10.1259/bjr.20160363. Epub 2016 Jul 22. Br J Radiol. 2018. PMID: 27376170 Free PMC article. Review.