Revision of a failed cemented total hip prosthesis with insertion of an acetabular component without cement and a femoral component with cement. A five to eight-year follow-up study
- PMID: 8698734
- DOI: 10.2106/00004623-199607000-00002
Revision of a failed cemented total hip prosthesis with insertion of an acetabular component without cement and a femoral component with cement. A five to eight-year follow-up study
Abstract
Sixty-one consecutive so-called hybrid revision total hip arthroplasties were performed in fifty-five patients by one surgeon, from 1986 through 1988, for mechanical failure of a cemented total hip prosthesis. In all of the patients, the acetabular and femoral components were revised to a porous-coated Harris-Galante acetabular component inserted without cement and an Iowa femoral component inserted with cement. Contemporary cementing techniques were used, but structural bone graft was not. The over-all prevalence of repeat revision for aseptic loosening was 0 per cent for the acetabular components and 3 per cent (two hips) for the femoral components. In addition, 2 per cent (one) of the acetabular components and 5 per cent (three) of the femoral components demonstrated radiographic evidence of loosening. In the forty-three patients (forty-nine hips) who were alive at an average of seventy-four months (range, sixty to ninety-five months) after the revision, none of the acetabular components and 2 per cent (one) of the femoral components were revised again for aseptic loosening. An additional 2 per cent (one) of the acetabular components and 6 per cent (three) of the femoral components were radiographically loose. Ninety-eight per cent (forty-one) of the forty-two living patients (98 per cent [forty-seven] of the forty-eight hips) who had a clinical examination at least five years after the revision had increased function; 90 per cent (thirty-eight) of these patients (forty-four [92 per cent] of the hips) were satisfied with the result. The group that had a hybrid revision was compared with a group of seventy patients (seventy-four hips) who had had a revision total hip arthroplasty with use of contemporary cementing techniques for both components. These revisions had been performed by the same surgeon, before he performed the hybrid revisions, and the prevalence of repeat revision of the acetabular component was 7 per cent (five hips) and that of the femoral component was 4 per cent (three hips). In addition, 16 per cent (twelve) of the acetabular components and 3 per cent (two) of the femoral components were radiographically loose. The comparison group was not a consecutive series, as only the patients who had had radiographs made five to eight years after the revision were evaluated. In the fifty-two such patients (fifty-six hips) who were alive at five years after the revision with cement (average duration of radiographic follow-up, seventy-seven months; range, sixty to ninety-nine months), 9 per cent (five) of the acetabular components and 5 per cent (three) of the femoral components were revised again for aseptic loosening. An additional 21 per cent (twelve) of the acetabular components and 4 per cent (two) of the femoral components were radiographically loose. The results of the present study demonstrated a significant improvement (p = 0.0001) in the survival of the acetabular component of so-called hybrid revision total hip arthroplasties compared with that of revision total hip arthroplasties with cement performed by the same surgeon and followed for a comparable period.
Similar articles
-
Charnley total hip arthroplasty with use of improved techniques of cementing. The results after a minimum of fifteen years of follow-up.J Bone Joint Surg Am. 1997 Jan;79(1):53-64. J Bone Joint Surg Am. 1997. PMID: 9010186
-
Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study.J Bone Joint Surg Am. 1995 Dec;77(12):1845-52. doi: 10.2106/00004623-199512000-00008. J Bone Joint Surg Am. 1995. PMID: 8550652
-
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.J Bone Joint Surg Am. 1999 Feb;81(2):247-55. doi: 10.2106/00004623-199902000-00012. J Bone Joint Surg Am. 1999. PMID: 10073588
-
Closed reduction for congenital dysplasia of the hip. Functional and radiographic results after an average of thirty years.J Bone Joint Surg Am. 1994 Dec;76(12):1777-92. doi: 10.2106/00004623-199412000-00004. J Bone Joint Surg Am. 1994. PMID: 7989383 Review.
-
Jumbo cups and morsalized graft.Orthop Clin North Am. 1998 Apr;29(2):249-54. doi: 10.1016/s0030-5898(05)70323-0. Orthop Clin North Am. 1998. PMID: 9553570 Review.
Cited by
-
Outcomes of Cement in Cement Revision, in Revision Total Hip Arthroplasty.Open Access Maced J Med Sci. 2019 Dec 12;7(23):4059-4065. doi: 10.3889/oamjms.2019.710. eCollection 2019 Dec 15. Open Access Maced J Med Sci. 2019. PMID: 32165952 Free PMC article.
-
What Can We Learn From 20-year Followup Studies of Hip Replacement?Clin Orthop Relat Res. 2016 Feb;474(2):402-7. doi: 10.1007/s11999-015-4260-7. Clin Orthop Relat Res. 2016. PMID: 25800375 Free PMC article.
-
Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trč-Cingr cup.Int Orthop. 2014 May;38(5):935-40. doi: 10.1007/s00264-013-2269-7. Epub 2014 Jan 16. Int Orthop. 2014. PMID: 24430429 Free PMC article.
-
Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem: 5- to 16-year results of 163 cases.Acta Orthop. 2014 Dec;85(6):562-9. doi: 10.3109/17453674.2014.958809. Epub 2014 Sep 1. Acta Orthop. 2014. PMID: 25175667 Free PMC article.
-
Clinical biomechanics of wear in total hip arthroplasty.Iowa Orthop J. 2003;23:1-12. Iowa Orthop J. 2003. PMID: 14575243 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources