Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1996 Mar-Apr;12(3):341-6.
doi: 10.3928/1081-597X-19960301-07.

Photorefractive keratectomy for myopia with a 6-mm beam diameter

Affiliations
Clinical Trial

Photorefractive keratectomy for myopia with a 6-mm beam diameter

S I Shah et al. J Refract Surg. 1996 Mar-Apr.

Abstract

Background: Earlier studies have reported clinical outcomes for up to 2 years following photorefractive keratectomy (PRK) using a 5.0-mm treatment zone with the Summit excimer laser. We present results of PRK using a 6-mm ablation zone with the same laser.

Methods: Forty-five eyes of 45 patients underwent excimer laser PRK for correction of myopia using a 6-mm excimer laser beam diameter. Attempted corrections ranged from 1.50 diopters (D) to 6.00 D. Data on outcomes of uncorrected visual acuity, spectacle-corrected visual acuity, predictability, corneal haze, subjective glare/halo effects, and patient satisfaction with the procedure were analyzed over a follow-up period of 6 months.

Results: All patients obtained a postoperative uncorrected visual acuity of at least 20/40; 28 eyes (62%) achieved at least 20/20. Postoperative spectacle-corrected visual acuity was at least 20/20 in all patients; no patients lost more than one Snellen line of spectacle-corrected visual acuity. Twenty-eight patients (62.2%) achieved within +/-0.50 D of the attempted correction; 40 patients (84.4%) achieved within +/-1.00 D. Mean spherical equivalent refraction was -4.99 D preoperatively and +0.44 D at 1 month, +0.04 D at 3 months, and +0.09 D at 6 months. At 6 months, 40 eyes (88.9%) were graded as clear, 4 eyes (8.9%) as having trace subepithelial haze, and 1 eye (2.2%) as having mild subepithelial haze. The mean glare/halo index for all of the patients was 0.59 on a scale of 0 to 5. Mean subjective patient satisfaction was 4.68 (on the same scale).

Conclusions: Clinical outcomes following excimer laser PRK for myopia using a 6-mm treatment zone are encouraging. Postoperative subjective glare/halo were minimal, suggesting an optical advantage in using the larger ablation zone.

PubMed Disclaimer

Publication types

LinkOut - more resources