Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Aug;37(8):1398-402.

Comparison between thallium-201 and technetium-99m-tetrofosmin uptake with sustained low flow and profound systolic dysfunction

Affiliations
  • PMID: 8708783
Free article
Comparative Study

Comparison between thallium-201 and technetium-99m-tetrofosmin uptake with sustained low flow and profound systolic dysfunction

B A Koplan et al. J Nucl Med. 1996 Aug.
Free article

Abstract

Technetium-99m-tetrofosmin uptake was compared to that of 201Tl in the setting of low flow and systolic dysfunction.

Methods: In nine open-chested dogs, a severe left anterior descending (LAD) coronary artery stenosis resulted in a 54.3% mean flow reduction and decreased left ventricular thickening from 21% +/- 1% to -3 +/- 2%. After 30 min, 37 MBq (1 mCi) of 201Tl and microspheres were injected and initial and 2-hr redistribution images acquired. Two hours later, 370 MBq (10 mCi) of 99mTc-tetrofosmin and microspheres were injected and an image was obtained. LAD: left circumflex (LCX) count ratios for both tracers and flows were calculated by well counting postmortem, and 201Tl and 99mTc-tetrofosmin defect magnitudes were determined by quantitative image analysis.

Results: LAD:LCx flow ratios were similar during 201Tl and 99mTc-tetrofosmin injections (0.48 +/- 0.04 versus 0.49 +/- 0.05, p = n.s.). Final 201Tl activity (0.66 +/- 0.04) was significantly higher than 99mTc-tetrofosmin (0.55 +/- 0.05; p < 0.05). LAD/LCx 99mTc-tetrofosmin image defect count ratio was similar to 201Tl defect count ratio on the initial rest 201Tl scan (0.57 +/- 0.03 versus 0.56 +/- 0.02, p = ns), but significantly less than 201Tl defect count ratio at 2 hr (0.57 +/- 0.03 versus 0.65 +/- 0.02, p < 0.05).

Conclusion: In a low-flow model with profound systolic dysfunction, myocardial 99mTc-tetrofosmin uptake ( > 50%) reflective of viability was observed in the asynergic zone perfused by the stenotic LAD.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources