Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996;14(3):227-33.
doi: 10.1016/0730-725x(95)02102-y.

Cerebral arteriovenous malformations: improved nidus demarcation by means of dynamic tagging MR-angiography

Affiliations
Comparative Study

Cerebral arteriovenous malformations: improved nidus demarcation by means of dynamic tagging MR-angiography

M Essig et al. Magn Reson Imaging. 1996.

Abstract

Our purpose was to further improve the target volume definition for radiosurgical treatment of cerebral arteriovenous malformations (AVMs) by means of dynamic MRA (dMRA) using a blood bolus tagging sequence. We therefore compare this technique with 3D-TOF-MRA and transfemoral high resolution angiography in plain film technique. Twenty patients with angiographically proven cerebral AVMs were investigated by dMRA, TOF-MRA, and conventional angiography during the MR-assisted radiosurgical planning protocol. The patient's head was fixed in an MR-compatible stereotactic device. The different angiography techniques were evaluated by consensus of two radiologists. AVMs were characterized by the number and origin of feeding arteries, the maximum diameter of the AVM nidus, and the venous drainage pattern. Dynamic MRA was able to demonstrate the complete AVM characteristics and hemodynamics in 12 out of 20 patients. In three patients with an AVM nidus smaller than 1 cm in diameter the technique could not reliably depict the malformation. Technical problems due to steel screws and pins in the initially used stereotactic frame occurred in five patients. Due to reduced vessel overlap and the lack of disturbances caused by formations with short T1 time, dMRA was superior to TOF-MRA in the detection and the exact localization of the AVM nidus in four patients. We conclude that dMRA is able to demonstrate reliably AVM characteristics and hemodynamics in AVMs with a nidus larger than 1 cm in diameter. Because of the improved demarcation of the AVM nidus, this technique may be a valuable adjunct to radiosurgery planning of cerebral AVMs.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources