Radioimmunoassay for quantitation of 2',3'-didehydro-3'-deoxythymidine (D4T) in human plasma
- PMID: 8726021
- PMCID: PMC163351
- DOI: 10.1128/AAC.40.6.1472
Radioimmunoassay for quantitation of 2',3'-didehydro-3'-deoxythymidine (D4T) in human plasma
Abstract
2',3'-Didehydro-3'-deoxythymidine (D4T, or stavudine) has been recently approved for the treatment of AIDS. In the present study, a specific and sensitive radioimmunoassay (RIA) was developed for the quantitation of D4T in human plasma. The RIA is a double-antibody competitive binding assay which uses anti-D4T antiserum raised in rabbits as the primary antibody, a tritiated derivative of D4T as the radioactive tracer, and goat anti-rabbit immunoglobulin G as the secondary antibody. No cross-reaction between D4T and various nucleoside analogs was detected. The limit of quantitation of the method approximated 20 ng/ml. Replicate analyses of quality control samples (40 to 3,500 ng/ml) had satisfactory intra- and interassay precision (coefficient of variation, 1.7 to 16.7%) and accuracy (deviation, -9.5 to +21.0). This newly developed RIA was successfully used in the monitoring of plasma drug levels in healthy volunteers receiving an oral dose of D4T.