Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Feb;14(4):475-81.
doi: 10.1016/0731-7085(95)01652-x.

Comparison of two extraction methods for determination of propranolol and furosemide in human plasma by mixed-mode chromatography

Affiliations
Comparative Study

Comparison of two extraction methods for determination of propranolol and furosemide in human plasma by mixed-mode chromatography

M Walshe et al. J Pharm Biomed Anal. 1996 Feb.

Abstract

An isocratic high performance liquid chromatographic method is described for the determination of the beta-adrenergic blocking drug, propranolol, and the diuretic, furosemide, in human plasma. The two compounds and the internal standard were extracted from plasma using a two-step extraction technique. Propranolol and pindolol (internal standard) were first extracted from alkaline plasma into diethyl ether; this was followed by extraction of furosemide into acidified ether: hexane (65:35). The two extracts were then combined and evaporated under nitrogen, and the reconstituted residues were analysed on a C18/SCX reversed-phase/cation exchange column with a mobile phase of acetonitrile: 0.1 M sodium acetate pH 4 (33:67). The drugs and the internal standard were detected by UV absorption at 230 nm. The drugs were also extracted from plasma by a column-switching technique utilizing a ten-port valve. The drug compounds were retained on a C18 pre-column. A comparison of RSD for within-batch (intra-assay) and between-batch (inter-assay) runs for both methods was carried out, the liquid/liquid extraction method giving better recovery values. The calibration graphs were linear from 25-300 ng ml-1 for furosemide and 50-400 ng ml-1 for propranolol. Recovery values were > 90.0% by liquid/liquid extraction and > 76.0% by column switching.