Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreas
- PMID: 873073
- DOI: 10.2337/diab.26.7.663
Normalization of glycemia in diabetics during meals with insulin and glucagon delivery by the artificial pancreas
Abstract
An extracorporeal "closed-loop" system has been employed to maintain glycemia in the normal range during consumption of meals in nine insulin-treated diabetics. This artificial pancreas system incorporated continuous blood glucose monitoring (0.05 ml. per minute, delay time 90 seconds), a computer programed to respond to glycemia, and a hormone delivery system. Intravenous insulin delivery rates were determined by control parameters responsive to both glucose concentration and its rate of change. Because insulin-dependent diabetics often defend themselves poorly against hypoglycemia (in some cases due to inadequate glucagon responses), the instrument was also programed for exogenous glucagon delivery. A priori selection of ideal parameters for insulin and glucagon delivery for each individual is not yet possible. Consequently, when the parameters were used for the first time on each subject, they were varied over a reasonable range. This approach resulted in a corresponding variety of glycemic responses, the average of which characterized a set of initial parameters that is generally applicable. Appropriate control parameters are presented that successfully prevented hypoglycemia. Glucagon delivery directly related to glycemia appeared sufficient for this purpose, thus obviating the need for dextrose administration. This system provides a technique for complete normalization of blood glucose concentration in the types of diabetics tested, during both fed and interprandial periods. It has yielded insights essential to the development of more sophisticated future devices.
Similar articles
-
Insulin, glucagon, and amino acids during glycemic control by the artificial pancreas in diabetic man.Metabolism. 1980 Apr;29(4):321-32. doi: 10.1016/0026-0495(80)90005-0. Metabolism. 1980. PMID: 6990172
-
[Artificial pancreas: study methods and control of glycemia equilibrium in diabetic patients].Boll Soc Ital Biol Sper. 1979 May 30;55(10):961-6. Boll Soc Ital Biol Sper. 1979. PMID: 508411 Italian.
-
Control of blood glucose in diabetics using an artificial pancreas.Aust N Z J Med. 1977 Jun;7(3):280-6. doi: 10.1111/j.1445-5994.1977.tb03687.x. Aust N Z J Med. 1977. PMID: 334138
-
Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.Diabetes Technol Ther. 2016 Feb;18 Suppl 2(Suppl 2):S253-63. doi: 10.1089/dia.2015.0345. Diabetes Technol Ther. 2016. PMID: 26784131 Free PMC article. Review.
-
Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.J Artif Organs. 2016 Sep;19(3):209-18. doi: 10.1007/s10047-016-0904-y. Epub 2016 May 3. J Artif Organs. 2016. PMID: 27142278 Review.
Cited by
-
Linear quadratic gaussian-based closed-loop control of type 1 diabetes.J Diabetes Sci Technol. 2007 Nov;1(6):834-41. doi: 10.1177/193229680700100606. J Diabetes Sci Technol. 2007. PMID: 19756210 Free PMC article.
-
In silico evaluation of a control system and algorithm for automated insulin infusion in the ICU setting.Biomed Eng Online. 2010 Jul 20;9:35. doi: 10.1186/1475-925X-9-35. Biomed Eng Online. 2010. PMID: 20642855 Free PMC article.
-
Assessment of an algorithm for the artificial B-cell using the normal insulin-glucose relationship in diabetic dogs and men.Diabetologia. 1980;18(2):97-107. doi: 10.1007/BF00290484. Diabetologia. 1980. PMID: 6988280
-
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility.J Diabetes Sci Technol. 2023 Nov;17(6):1493-1505. doi: 10.1177/19322968231195081. Epub 2023 Sep 25. J Diabetes Sci Technol. 2023. PMID: 37743740 Free PMC article. Review.
-
Automated closed-loop control of diabetes: the artificial pancreas.Bioelectron Med. 2018 Nov 7;4:14. doi: 10.1186/s42234-018-0015-6. eCollection 2018. Bioelectron Med. 2018. PMID: 32232090 Free PMC article. Review.
MeSH terms