Regional myocardial motion and thickening assessed at rest by ECG-gated 99mTc-MIBI emission tomography and by magnetic resonance imaging
- PMID: 8753679
- DOI: 10.1007/BF01084364
Regional myocardial motion and thickening assessed at rest by ECG-gated 99mTc-MIBI emission tomography and by magnetic resonance imaging
Abstract
We have validated ECG-gated emission tomography using technetium-99m methoxyisobutylisonitrile for the assessment of regional ventricular function by comparing it with cine magnetic resonance imaging (MRI). Gated tomography was performed at rest in 24 patients referred for myocardial perfusion imaging [17 males and seven females with a mean age of 58 years, nine of whom had had a previous myocardial infarction (MI)]. Scores were assigned to each of nine myocardial segments for wall motion and for thickening. Cine MRI was analysed in an identical fashion. Four out of 216 (2%) segments were uninterpretable by gated tomography because of inadequate tracer uptake. In eight patients without coronary artery disease (CAD), wall motion and thickening were normal by both methods. Gated tomography showed abnormal wall motion or thickening in all patients with previous MI and in five of seven patients with CAD but no prior MI. Association between wall motion and thickening was good (rs=0. 86). Overall, there was good agreement between gated tomography and MRI for both wall motion (178/212 segments, kappa=0.66) and wall thickening (184/212 segments, kappa=0.69). In segments with severely reduced perfusion, however, there was poorer agreement (kappa=0.31). Interobserver and intraobserver agreement was high (kappa from 0.61 to 0.78). Thus, in patients investigated for CAD, there is good overall agreement between gated tomography and MRI but the agreement is lower in segments with severe perfusion defects.
Similar articles
-
Gated technetium-99m-tetrofosmin SPECT and cine MRI to assess left ventricular contraction.J Nucl Med. 1997 Mar;38(3):438-42. J Nucl Med. 1997. PMID: 9074534
-
Comparative study of single-injection, single-acquisition 99mTc-MIBI gated SPET and stress-rest perfusion SPET for the evaluation of myocardial viability after bypass surgery in coronary artery disease.Eur J Nucl Med. 2000 Dec;27(12):1747-53. doi: 10.1007/s002590000386. Eur J Nucl Med. 2000. PMID: 11189935
-
Combined analysis of resting regional wall thickening and stress perfusion with electrocardiographic-gated technetium 99m-labeled sestamibi single-photon emission computed tomography: prediction of stress defect reversibility.J Nucl Cardiol. 1997 Jan-Feb;4(1 Pt 1):3-10. doi: 10.1016/s1071-3581(97)90043-x. J Nucl Cardiol. 1997. PMID: 9138837
-
The role of gated myocardial perfusion scintigraphy (GMPS) in myocarditis: a case report and review of the literature.Nucl Med Rev Cent East Eur. 2011;14(2):112-5. doi: 10.5603/nmr.2011.00026. Nucl Med Rev Cent East Eur. 2011. PMID: 22219153 Review.
-
The added value of simultaneous myocardial perfusion and left ventricular function.Curr Opin Cardiol. 1999 Nov;14(6):460-3. doi: 10.1097/00001573-199911000-00002. Curr Opin Cardiol. 1999. PMID: 10579060 Review.
Cited by
-
Prognostic Value of Early Evaluation of Left Ventricular Dyssynchrony After Myocardial Infarction.Mol Imaging Biol. 2019 Aug;21(4):654-659. doi: 10.1007/s11307-018-1279-7. Mol Imaging Biol. 2019. PMID: 30225761
-
Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography.J Nucl Cardiol. 2000 Jul-Aug;7(4):301-11. doi: 10.1067/mnc.2000.105279. J Nucl Cardiol. 2000. PMID: 10958271
-
Comparison between segmental wall motion and wall thickening in patients with coronary artery disease using quantitative gated SPECT software.Int J Card Imaging. 2000 Aug;16(4):283-91. doi: 10.1023/a:1026574431560. Int J Card Imaging. 2000. PMID: 11219600 Clinical Trial.
-
Heterogeneity of myocardial wall motion and thickening in the left ventricle evaluated with quantitative gated SPECT.J Nucl Cardiol. 2000 Jul-Aug;7(4):296-300. doi: 10.1067/mnc.2000.104958. J Nucl Cardiol. 2000. PMID: 10958270
-
Nitrate-enhanced gated technetium 99m sestamibi SPECT for evaluating regional wall motion at baseline and during low-dose dobutamine infusion in patients with chronic coronary artery disease and left ventricular dysfunction: comparison with two-dimensional echocardiography.J Nucl Cardiol. 2000 Sep-Oct;7(5):426-31. doi: 10.1067/mnc.2000.108029. J Nucl Cardiol. 2000. PMID: 11083190
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous