Posttraumatic high-flow priapism treated by N-butyl-cyanoacrylate embolization
- PMID: 8755084
Posttraumatic high-flow priapism treated by N-butyl-cyanoacrylate embolization
Abstract
A patient with high-flow priapism was treated by transcatheter embolization of a posttraumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate (NBCA), resulting in complete detumescence. Erectile function has been preserved during a 3-month follow-up. Only two patients with NBCA embolization for high-flow priapism have been reported previously.
Comment in
-
Re: Embolization of posttraumatic high-flow priapism.Cardiovasc Intervent Radiol. 1997 May-Jun;20(3):237-8. doi: 10.1007/s002709900146. Cardiovasc Intervent Radiol. 1997. PMID: 9134853 No abstract available.
Similar articles
-
Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism.Cardiovasc Intervent Radiol. 2016 Sep;39(9):1343-6. doi: 10.1007/s00270-016-1356-8. Epub 2016 May 10. Cardiovasc Intervent Radiol. 2016. PMID: 27164971
-
Re: Embolization of posttraumatic high-flow priapism.Cardiovasc Intervent Radiol. 1997 May-Jun;20(3):237-8. doi: 10.1007/s002709900146. Cardiovasc Intervent Radiol. 1997. PMID: 9134853 No abstract available.
-
Superselective embolization in posttraumatic priapism with glubran 2 acrylic glue.Cardiovasc Intervent Radiol. 2004 Sep-Oct;27(5):544-8. doi: 10.1007/s00270-003-0210-y. Epub 2004 Jun 3. Cardiovasc Intervent Radiol. 2004. PMID: 15383862
-
[Percutaneous superselective bilateral embolization for the therapy of traumatic juvenile arterial priapism].Rofo. 1997 Mar;166(3):263-5. doi: 10.1055/s-2007-1015422. Rofo. 1997. PMID: 9156602 Review. German. No abstract available.
-
Superselective microcoil embolization in the management of high-flow priapism.J Vasc Interv Radiol. 1998 Jan-Feb;9(1 Pt 1):85-9. doi: 10.1016/s1051-0443(98)70488-9. J Vasc Interv Radiol. 1998. PMID: 9468400 Review. No abstract available.
Cited by
-
[Diagnosis and management of priapism].Urologe A. 2015 May;54(5):654-61. doi: 10.1007/s00120-015-3799-y. Urologe A. 2015. PMID: 25987330 German.
-
Can microcatheters be cleaned for reuse after NBCA embolization? Cleaning technique with gelatin sponge particles.Jpn J Radiol. 2015 Aug;33(8):509-16. doi: 10.1007/s11604-015-0446-x. Epub 2015 Jun 30. Jpn J Radiol. 2015. PMID: 26123019
-
High flow priapism: diagnosis and treatment in pediatric population.Pediatr Surg Int. 2011 Nov;27(11):1217-21. doi: 10.1007/s00383-011-2911-7. Epub 2011 May 5. Pediatr Surg Int. 2011. PMID: 21544645
-
[A bicycle fall with consequences].Urologie. 2023 Dec;62(12):1309-1314. doi: 10.1007/s00120-023-02202-5. Epub 2023 Oct 10. Urologie. 2023. PMID: 37816873 Free PMC article. German. No abstract available.
-
Evaluation and management of priapism: 2009 update.Nat Rev Urol. 2009 May;6(5):262-71. doi: 10.1038/nrurol.2009.50. Nat Rev Urol. 2009. PMID: 19424174 Free PMC article. Review.