Dentin bonding system. Part II: Effect of crosshead speed
- PMID: 8761519
Dentin bonding system. Part II: Effect of crosshead speed
Abstract
Dentin bond strengths are normally evaluated by conducting mechanical tests in tensile and/or shear mode at a certain level of crosshead speed. According to the literature review, crosshead speed is varied in a relatively wide range from 0.1 mm/min to 10.0 mm/min (with the exception of a few studies conducted above 10.0 mm/min). It was also found that crosshead speeds of 0.5, 1.0, 2.0 and 5.0 mm/min were commonly employed to evaluate dentin bond strengths for both tensile and shear modes, although no rationale for selecting the crosshead speed was described in the articles. For testing dentin bond strengths, no plastic deformation should be involved, and fracture only should take place during the fracturing process. With the Scotchbond Multiple-Purpose/Z100 bonding system, tensile bond strengths were evaluated at crosshead speeds of 0.1, 0.5, 1.0, 5.0 and 10.0 mm/min. It was found that (i) there was no strain rate sensitivity when the test was conducted below the 1.0 mm/min crosshead speed, and (ii) if the crosshead speed exceeded 1.0 mm/min, a strain rate dependency of the tensile bond strengths was observed. Knowledge that the composite resin (Z100) did not exhibit strain rate dependency influenced the conclusion that (iii) the above observed strain rate dependency was solely due to the mechanical response from the bonding interface region.
Similar articles
-
Dentin bond strengths of two ceramic inlay systems after cementation with three different techniques and one bonding system.J Prosthet Dent. 2003 Mar;89(3):275-81. doi: 10.1067/mpr.2003.37. J Prosthet Dent. 2003. PMID: 12644803 Clinical Trial.
-
Tensile bond strengths of resin cements to bovine dentin using resin coating.Am J Dent. 2003 Sep;16 Spec No:41A-46A. Am J Dent. 2003. PMID: 14674498
-
Influence of crosshead speed on micro-tensile bond strength of two-step adhesive systems.Dent Mater. 2006 May;22(5):420-5. doi: 10.1016/j.dental.2005.04.031. Epub 2005 Jul 21. Dent Mater. 2006. PMID: 16038968
-
Tensile bond strength of Er,Cr:YSGG laser-irradiated human dentin and analysis of dentin-resin interface.Dent Mater. 2007 May;23(5):570-8. doi: 10.1016/j.dental.2006.03.016. Epub 2006 Jul 3. Dent Mater. 2007. PMID: 16820200
-
Do dentin bond strength tests serve a useful purpose?J Adhes Dent. 1999 Spring;1(1):57-67. J Adhes Dent. 1999. PMID: 11725686 Review.