Abstract
The author and Sulzer Medical Technology Ltd, Switzerland, have developed a new generation of metal on metal bearing total hip joints. The design is different than the McKee type prostheses in that the cobalt chrome alloy heads and cups (Metasul) are of the highest precision with controlled loose fitting. These allow low friction and low wear of approximately 5 micrometers per year. It is anticipated that debris related late loosening will be avoided by the use of this design. Approximately 30,000 Metasul hearings have been produced. The first 110 Weber metal on metal hip implants have been analyzed. No adverse effects from the wear of the new metal on metal components have been noted in this series.
Similar articles
-
Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.Clin Orthop Relat Res. 2016 Oct;474(10):2126-33. doi: 10.1007/s11999-016-4920-2. Clin Orthop Relat Res. 2016. PMID: 27278679 Free PMC article.
-
Cobalt chromium molybdenum metal combination for modular hip prostheses.Clin Orthop Relat Res. 1996 Aug;(329 Suppl):S35-47. doi: 10.1097/00003086-199608001-00004. Clin Orthop Relat Res. 1996. PMID: 8769321 Review.
-
Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.Orthop Traumatol Surg Res. 2009 Nov;95(7):478-90. doi: 10.1016/j.otsr.2009.07.007. Epub 2009 Oct 3. Orthop Traumatol Surg Res. 2009. PMID: 19801209
-
Effect of low-friction ion-treated femoral heads on polyethylene wear rates.Clin Orthop Relat Res. 2000 Jan;(370):183-91. doi: 10.1097/00003086-200001000-00017. Clin Orthop Relat Res. 2000. PMID: 10660712
-
The argument for the use of Metasul as an articulation surface in total hip replacement.Clin Orthop Relat Res. 2004 Dec;(429):80-5. doi: 10.1097/01.blo.0000150343.66755.79. Clin Orthop Relat Res. 2004. PMID: 15577470 Review.
Cited by
-
Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.Int Orthop. 2009 Dec;33(6):1537-42. doi: 10.1007/s00264-008-0679-8. Epub 2008 Nov 5. Int Orthop. 2009. PMID: 18985349 Free PMC article.
-
Long-Term Results of a Second-Generation, Small-Diameter, Metal-On-Metal Bearing in Primary Total Hip Arthroplasty at 14-year Follow-Up.Materials (Basel). 2020 Jan 24;13(3):557. doi: 10.3390/ma13030557. Materials (Basel). 2020. PMID: 31991553 Free PMC article.
-
Study of the polycarbonate-urethane/metal contact in different positions during gait cycle.Biomed Res Int. 2014;2014:548968. doi: 10.1155/2014/548968. Epub 2014 Aug 27. Biomed Res Int. 2014. PMID: 25247180 Free PMC article.
-
Metal on Metal Bearing in Total Hip Arthroplasty and Its Impact on Synovial Cell Count.J Clin Med. 2020 Oct 18;9(10):3349. doi: 10.3390/jcm9103349. J Clin Med. 2020. PMID: 33081071 Free PMC article.
-
Immunoglobulin A Nephropathy in a Patient With Bilateral Metal-on-Metal Hip Arthroplasty.Arthroplast Today. 2024 Jun 5;27:101407. doi: 10.1016/j.artd.2024.101407. eCollection 2024 Jun. Arthroplast Today. 2024. PMID: 38946922 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources