Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996;18(2):89-96.
doi: 10.1007/BF01795225.

Viscoelastic properties of human arteries. Methodology and preliminary results

Affiliations

Viscoelastic properties of human arteries. Methodology and preliminary results

E Rosset et al. Surg Radiol Anat. 1996.

Abstract

In order to study the biomechanical properties of the arterial wall and to compare arteries with different histologic structures, we designed a device that allows testing of arterial segments under near-physiologic conditions. A hydrodynamic generator simulates systolo-diastolic pressures in an open loop. An intraarterial pressure sensor and a sonomicrometer connected to two piezoelectric crystals placed in diametric opposition on the arterial wall allow computer calculation of compliance, stiffness, midwall radial arterial stress, Young modulus, and incremental modulus for a given arterial segment at a given pressure setting. Seven healthy common carotid artery (CCA) segments and seven healthy (superficial) femoral artery (FA) segments were studied immediately after removal from brain-dead donors between the ages of 18 and 35 years. Histologic examination was performed to determine the density of elastic fibers in the arterial wall. Hysteresis was observed in all segments regardless of pressure settings. Compliance was greater and modulus values and stiffness were lower in CCA than in FA. No evidence of structural change was noted after testing in the circulation loop. These preliminary results open the way to a wide variety of applications for our hydrodynamic circulation loop. Experiments will be undertaken to compare the mechanical properties of arteries before and after cryopreservation.

PubMed Disclaimer

References

    1. J Vasc Surg. 1993 Feb;17(2):349-55; discussion 355-6 - PubMed
    1. Circ Res. 1979 Mar;44(3):420-9 - PubMed
    1. Cardiovasc Drugs Ther. 1989 Jun;3(3):445-58 - PubMed
    1. Physiol Rev. 1978 Apr;58(2):397-460 - PubMed
    1. Circ Res. 1966 Mar;18(3):278-92 - PubMed