Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Sep;16(5):834-40.
doi: 10.1097/00004647-199609000-00008.

Distribution volume ratios without blood sampling from graphical analysis of PET data

Affiliations

Distribution volume ratios without blood sampling from graphical analysis of PET data

J Logan et al. J Cereb Blood Flow Metab. 1996 Sep.

Abstract

The distribution volume ratio (DVR), which is a linear function of receptor availability, is widely used as a model parameter in imaging studies. The DVR corresponds to the ratio of the DV of a receptor-containing region to a nonreceptor region and generally requires the measurement of an arterial input function. Here we propose a graphical method for determining the DVR that does not require blood sampling. This method uses data from a nonreceptor region with an average tissue-to-plasma efflux constant k2 to approximate the plasma integral. Data from positron emission tomography studies with [11C]raclopride (n = 20) and [11C]d-threo-methylphenidate ([11C]dMP) (n = 8) in which plasma data were taken and used to compare results from two graphical methods, one that uses plasma data and one that does not. k2 was 0.163 and 0.051 min-1 for [11C]raclopride and [11C]dMP, respectively. Results from both methods were very similar, and the average percentage difference between the methods was -0.11% for [11C]raclopride and 0.46% for [11C]dMP for DVR of basal ganglia (BG) to cerebellum (CB). Good agreement between the two methods was also achieved for DVR images created by both methods. This technique provides an alternative method of analysis not requiring blood sampling that gives equivalent results for the two ligands studied. It requires initial studies with blood sampling to determine the average kinetic constant and to test applicability. In some cases, it may be possible to neglect the k2 term if the BG/CB ratio becomes reasonably constant for a sufficiently long period of time over the course of the experiment.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources