Comparison of two quantitative hepatitis C virus reverse transcriptase PCR assays
- PMID: 8788997
- PMCID: PMC228779
- DOI: 10.1128/jcm.34.2.261-264.1996
Comparison of two quantitative hepatitis C virus reverse transcriptase PCR assays
Abstract
A quantitative hepatitis C virus reverse transcriptase PCR (HCV RT-PCR) assay established in our laboratory was compared with the Roche Amplicor HCV Monitor test kit for agreement of test results and intra-assay variability. Both assays rely on reverse transcription and amplification of extracted RNA from patients' sera together with an internal RNA standard derived from the 5'-noncoding region of HCV. A panel of clinical serum samples (n = 33) was quantitatively analyzed in parallel by both test systems. The methods demonstrated substantial agreement between 1 x 10(3) and 5 x 10(5) HCV RNA molecules per ml of serum. However, with sera containing more than 5 x 10(5) copies per ml, according to our in-house assay, the results diverged on average in a nonacceptable range of 2 orders of magnitude. Our in-house HCV RT-PCR assay measured up to 5 x 10(7) HCV-RNA molecules per ml in some serum samples. However, the Roche Amplicor HCV Monitor test kit did not detect more than 2 x 10(6) molecules in any of the serum samples tested. After dilution of serum samples prior to testing, an approximately 0.5 order of magnitude more HCV RNA molecules was detected by the Roche HCV test kit in sera containing high copy numbers (> 5 x 10(5) RNA copies according to the in-house assay). The in-house PCR and the Roche Amplicor HCV Monitor test kit revealed coefficients of variation of 6.2 and 7.5%, respectively.
Similar articles
-
Quantitative measurement of serum HCV RNA in patients with chronic hepatitis C: comparison between Amplicor HCV monitor system and branched DNA signal amplification assay.J Clin Lab Anal. 1998;12(2):121-5. doi: 10.1002/(sici)1098-2825(1998)12:2<121::aid-jcla8>3.0.co;2-d. J Clin Lab Anal. 1998. PMID: 9524297 Free PMC article.
-
Preclinical evaluation of AMPLICOR hepatitis C virus test for detection of hepatitis C virus RNA.J Clin Microbiol. 1995 Jul;33(7):1775-8. doi: 10.1128/jcm.33.7.1775-1778.1995. J Clin Microbiol. 1995. PMID: 7665645 Free PMC article.
-
Comparison of a competitive combined reverse transcription-PCR assay with a branched-DNA assay for hepatitis C virus RNA quantitation.J Clin Microbiol. 1996 Nov;34(11):2702-6. doi: 10.1128/jcm.34.11.2702-2706.1996. J Clin Microbiol. 1996. PMID: 8897168 Free PMC article.
-
Comparison of HCV RNA assays for the detection and quantification of hepatitis C virus RNA levels in serum of patients with chronic hepatitis C treated with interferon.J Med Virol. 1997 May;52(1):105-12. J Med Virol. 1997. PMID: 9131466
-
Enhanced amplification of hepatitis C virus (HCV) cDNA by PCR: detection of HCV RNA in archival sera.J Clin Microbiol. 1996 Jun;34(6):1581-2. doi: 10.1128/jcm.34.6.1581-1582.1996. J Clin Microbiol. 1996. PMID: 8735126 Free PMC article.
Cited by
-
Quantitative measurement of serum HCV RNA in patients with chronic hepatitis C: comparison between Amplicor HCV monitor system and branched DNA signal amplification assay.J Clin Lab Anal. 1998;12(2):121-5. doi: 10.1002/(sici)1098-2825(1998)12:2<121::aid-jcla8>3.0.co;2-d. J Clin Lab Anal. 1998. PMID: 9524297 Free PMC article.
-
Comparative study of different standardization concepts in quantitative competitive reverse transcription-PCR assays.J Clin Microbiol. 1998 Mar;36(3):628-33. doi: 10.1128/JCM.36.3.628-633.1998. J Clin Microbiol. 1998. PMID: 9508285 Free PMC article.
-
Risk and management of blood-borne infections in health care workers.Clin Microbiol Rev. 2000 Jul;13(3):385-407. doi: 10.1128/CMR.13.3.385. Clin Microbiol Rev. 2000. PMID: 10885983 Free PMC article. Review.
-
Acute hepatitis C virus structural gene sequences as predictors of persistent viremia: hypervariable region 1 as a decoy.J Virol. 1999 Apr;73(4):2938-46. doi: 10.1128/JVI.73.4.2938-2946.1999. J Virol. 1999. PMID: 10074143 Free PMC article.
-
Quantitative assay of hepatitis C virus RNA using an automated extraction system for specific capture with probes and paramagnetic particle separation.J Clin Microbiol. 2003 Feb;41(2):572-5. doi: 10.1128/JCM.41.2.572-575.2003. J Clin Microbiol. 2003. PMID: 12574248 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources