Validation of catheter semiquantitative culture technique for nonstaphylococcal organisms
- PMID: 8789025
- PMCID: PMC228807
- DOI: 10.1128/jcm.34.2.409-412.1996
Validation of catheter semiquantitative culture technique for nonstaphylococcal organisms
Abstract
The catheter semiquantitative culture roll tip technique has been validated as a discriminator between non-catheter-related bacteremias and catheter-related bacteremias (CRBs) caused by Staphylococcus species. However, this technique has not been specifically validated when used for the evaluation of catheters infected with organisms other than staphylococci. We reviewed catheters that had been submitted for semiquantitative roll tip culture as well as hospital records to determine clinical correlates of infection. Local infection and CRB were defined by standard criteria. Catheter-related sepsis (CRS) was defined as fever, leukocytosis, or hypotension which resolved with catheter removal, without another source of infection. For 195 catheters from 93 patients, gram-negative rods and enterococci were present on 36, fungi were on 25, Corynebacterium species were on 5, Bacillus species were on 3, Staphylococcus species were on 79, and 41 demonstrated no growth. Of 21 episodes of CRB or CRS due to nonstaphylococcal organisms, only 1 (questionable) episode was due to a catheter with < 15 CFU (P < 0.05). Eleven of these 21 episodes of CRB or CRS were due to gram-negative rods and enterococci, of which only the questionable episode was due to a catheter with < 15 CFU. Nine of these 21 episodes of CRB or CRS were due to fungi, none of which were associated with a catheter with < 15 CFU. The data for Staphylococcus species recapitulated published data (none of 21 CRB or CRS episodes were associated with catheters with < 15 CFU) and validated this retrospective technique. The data presented in this study validate the use of the semiquantitative culture technique for the evaluation of catheter-related infections caused by organisms other than staphylococci.
Similar articles
-
Catheter-related infections and blood cultures.Clin Lab Med. 1994 Mar;14(1):51-8. Clin Lab Med. 1994. PMID: 8181233 Review.
-
Sonicated vascular catheter tip cultures. Quantitative association with catheter-related sepsis and the non-utility of an adjuvant cytocentrifuge Gram stain.Am J Clin Pathol. 1996 Feb;105(2):210-5. doi: 10.1093/ajcp/105.2.210. Am J Clin Pathol. 1996. PMID: 8607447
-
Catheter-related bacteremia and fungemia. Reliability of two methods for catheter culture.Diagn Microbiol Infect Dis. 1992 Sep-Oct;15(7):575-8. doi: 10.1016/0732-8893(90)90033-r. Diagn Microbiol Infect Dis. 1992. PMID: 1424513
-
Laboratory diagnosis of catheter-related bacteremia.Scand J Infect Dis. 1991;23(5):583-8. doi: 10.3109/00365549109105182. Scand J Infect Dis. 1991. PMID: 1767254
-
Intravenous catheter-related infections.Adv Pediatr Infect Dis. 1995;10:337-68. Adv Pediatr Infect Dis. 1995. PMID: 7718211 Review.
Cited by
-
Biofilm production by multiresistant Corynebacterium striatum associated with nosocomial outbreak.Mem Inst Oswaldo Cruz. 2015 Apr;110(2):242-8. doi: 10.1590/0074-02760140373. Mem Inst Oswaldo Cruz. 2015. PMID: 25946249 Free PMC article.
-
Clinical characteristics of peripheral venous catheter-associated gram-negative bloodstream infection among patients with malignancy.PLoS One. 2020 Jan 30;15(1):e0228396. doi: 10.1371/journal.pone.0228396. eCollection 2020. PLoS One. 2020. PMID: 31999762 Free PMC article.
-
Vascular catheter-related infections: an endemic disease in healthcare institutions. An opinion paper of the Spanish Society of Cardiovascular Infections (SEICAV).Rev Esp Quimioter. 2024 Oct;37(5):387-400. doi: 10.37201/req/051.2024. Epub 2024 Jun 26. Rev Esp Quimioter. 2024. PMID: 38916720 Free PMC article. Review.
References
MeSH terms
LinkOut - more resources
Full Text Sources