Efficacy of the Steri-Shield filtered exhaust helmet in limiting bacterial counts in the operating room during total joint arthroplasty
- PMID: 8792255
- DOI: 10.1016/s0883-5403(96)80038-6
Efficacy of the Steri-Shield filtered exhaust helmet in limiting bacterial counts in the operating room during total joint arthroplasty
Abstract
Filtered exhaust helmets (space suits) have been reported as efficacious in decreasing wound infections following joint arthroplasty procedures; however, strict experimental control of the many variables related to the incidence of clinical infection has been lacking in these studies, making support of such conclusions difficult. Any potential benefit of filtered exhaust helmets in the control of infection rates can be logically assigned to the reduction of airborne bacterial counts within the operating room. A study was done using the Steri-Shield helmet (Bio-Medical Devices, Irvine, CA) to define its efficacy in limiting airborne bacterial contaminates during total joint arthroplasty. Forty-eight paired prosthetic hip and knee cases were evaluated using a block experimentation design. One case of each pair was done with all surgical and scrub personnel cloaked in Steri-Shield filtered exhaust helmets and the other with the same personnel in conventional paper hoods and masks. Air samples were obtained with an Anderson two-stage viable particle sampler (Anderson Samplers, Atlanta, GA) placed immediately adjacent to the wound. Quantitative microbial cultures were obtained. The filtered exhaust helmet evaluated in this study provided no increased protection against bacterial contamination in the area of the surgical field than conventional paper hoods and masks.
Similar articles
-
The effect of a portable HEPA-filtered body exhaust system on airborne microbial contamination in a conventional operating room.Infect Control Hosp Epidemiol. 1996 Jul;17(7):419-22. doi: 10.1086/647332. Infect Control Hosp Epidemiol. 1996. PMID: 8839798
-
Contamination Relative to the Activation Timing of Filtered-Exhaust Helmets.J Arthroplasty. 2016 Apr;31(4):776-80. doi: 10.1016/j.arth.2015.10.039. Epub 2015 Nov 10. J Arthroplasty. 2016. PMID: 26684270 Free PMC article.
-
Routes and sources of Staphylococcus aureus transmitted to the surgical wound during cardiothoracic surgery: possibility of preventing wound contamination by use of special scrub suits.Infect Control Hosp Epidemiol. 2001 Jun;22(6):338-46. doi: 10.1086/501910. Infect Control Hosp Epidemiol. 2001. PMID: 11519910
-
Do 'Surgical Helmet Systems' or 'Body Exhaust Suits' Affect Contamination and Deep Infection Rates in Arthroplasty? A Systematic Review.J Arthroplasty. 2016 Jan;31(1):225-33. doi: 10.1016/j.arth.2015.07.043. Epub 2015 Aug 1. J Arthroplasty. 2016. PMID: 26321627
-
Environment of care: Is it time to reassess microbial contamination of the operating room air as a risk factor for surgical site infection in total joint arthroplasty?Am J Infect Control. 2017 Nov 1;45(11):1267-1272. doi: 10.1016/j.ajic.2017.06.027. Epub 2017 Aug 14. Am J Infect Control. 2017. PMID: 28818359 Review.
Cited by
-
Sterility of the personal protection system in total joint arthroplasty.Clin Orthop Relat Res. 2011 Nov;469(11):3065-9. doi: 10.1007/s11999-011-1883-1. Clin Orthop Relat Res. 2011. PMID: 21671110 Free PMC article.
-
Is Your Surgical Helmet System Compromising the Sterile Field? A Systematic Review of Contamination Risks and Preventive Measures in Total Joint Arthroplasty.Clin Orthop Relat Res. 2025 Jun 1;483(6):972-990. doi: 10.1097/CORR.0000000000003383. Epub 2025 Feb 5. Clin Orthop Relat Res. 2025. PMID: 39915114
-
Unveiling the dynamics of intraoperative contamination in total hip arthroplasty: the discrepancy between particulate and microbial contamination in surgical site infection risk.Arthroplasty. 2024 Oct 1;6(1):49. doi: 10.1186/s42836-024-00272-0. Arthroplasty. 2024. PMID: 39350209 Free PMC article.
-
Intraoperative contamination and space suits: a potential mechanism.Eur J Orthop Surg Traumatol. 2014 Apr;24(3):409-13. doi: 10.1007/s00590-013-1178-1. Epub 2013 Feb 9. Eur J Orthop Surg Traumatol. 2014. PMID: 23412319
-
The Gown-glove Interface Is a Source of Contamination: A Comparative Study.Clin Orthop Relat Res. 2015 Jul;473(7):2291-7. doi: 10.1007/s11999-014-4094-8. Clin Orthop Relat Res. 2015. PMID: 25488405 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources