Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1996 Aug;34(8):1885-91.
doi: 10.1128/jcm.34.8.1885-1891.1996.

Quantitative assay of PCR-amplified hepatitis B virus DNA using a peroxidase-labelled DNA probe and enhanced chemiluminescence

Affiliations
Comparative Study

Quantitative assay of PCR-amplified hepatitis B virus DNA using a peroxidase-labelled DNA probe and enhanced chemiluminescence

A Erhardt et al. J Clin Microbiol. 1996 Aug.

Abstract

We have developed a sensitive and quantitative assay for hepatitis B virus (HBV) DNA in serum or plasma in which PCR and then microtiter hybridization analysis are used. Assay of HBV DNA in serum or plasma is important for demonstrating viral replication, indicating and monitoring antiviral therapy, determining the infectivities of virus carriers, and ensuring the safety of blood products. Under optimum conditions PCR can amplify one HBV DNA molecule to 10(8) copies, but detection of this amount of DNA still requires hybridization with labelled probes or a nested PCR. We labelled one strand of the PCR product with a biotinylated primer. The double-stranded amplicon was incubated in streptavidin-coated microplate wells. The nonlabelled strand was removed after denaturation of the double-stranded DNA with alkali, and the bound strand was hybridized with a peroxidase-coupled single-stranded probe. The amount of bound peroxidase was measured in a luminometer. Four picograms of amplicon was detectable in this system, whereas conventional ethidium bromide staining requires a 1,000 times higher amplicon concentration. The performance of the new assay was compared with those of nested PCR and a PCR system that uses a digoxigenin label, hybridization to a solid-phase adsorbed probe, and colorimetric detection. The chemiluminescence assay was found to be almost as sensitive as nested PCR and approximately five times more sensitive than the colorimetric test.

PubMed Disclaimer

References

    1. J Infect Dis. 1989 Jul;160(1):37-43 - PubMed
    1. J Med Virol. 1989 Apr;27(4):274-81 - PubMed
    1. Lancet. 1989 Sep 9;2(8663):588-91 - PubMed
    1. Res Virol. 1989 Jul-Aug;140(4):283-91 - PubMed
    1. J Clin Lab Anal. 1989;3(5):316-22 - PubMed

Publication types