Fourier transform infrared microscopy of calcified turkey leg tendon
- PMID: 8825234
- DOI: 10.1007/BF02509541
Fourier transform infrared microscopy of calcified turkey leg tendon
Abstract
Fourier transform infrared microscopy (FT-IRMS) was used to monitor spatial variations in the quality and quantity of the mineral phase in calcified turkey tendon. Spectral maps were generated by analysis of 50 microns x 50 microns areas within different regions of the tendon. Spectra of the transitional region, where nonmineralized matrix ends and mineralized matrix begins, revealed marked changes in the spectrally determined mineral-to-matrix ratio, whereas regions deeper into the mineralization front showed a relatively constant ratio. Since spectra of EDTA-demineralized matrix were similar to those of nonmineralized matrix, the nonmineralized regions of the tendon were used for spectral subtraction. The broad, relatively featureless contour of the mineral v1, v3 phosphate region (900-1200 cm-1) showed only subtle changes at different stages of mineralization. Second derivatives of these spectra were calculated and compared with those of synthetic, poorly crystalline hydroxyapatite (HA). The peak positions seen in second-derivative spectra of the mineral near the transitional region were within +/- 2 cm-1 of the least mature synthetic HAs whereas spectra of the mineral deeper into the mineralization front were within +/- 2 cm-1 of the most mature synthetic HAs. Spectra from cross- and longitudinal sections at equivalent positions in the tendon, and polarized FT-IRMS data were analyzed to determine the effect of mineral orientation on the parameters used to characterize the mineral. Spectra of cross- and longitudinal sections of the tendon showed no major differences in either the v1, v3 phosphate region or the amide I, II, or III components (1200-1800 cm-1). However, polarized FT-IR spectra revealed dramatic differences in both of these regions. Despite these differences, second-derivative analysis of the v1, v3 regions revealed no significant changes in the positions of the underlying bands used to characterize the environments of the phosphate ion in poorly crystalline HA. The results of this study demonstrate the power of FT-IRMS to monitor spatial variations of the mineral phase in calcified tissue. Also, the incorporation of polarized radiation provides a method capable of assessing the molecular orientation of the mineral phase relative to the collagen matrix.
Similar articles
-
Polarized FT-IR microscopy of calcified turkey leg tendon.Connect Tissue Res. 1996;34(3):203-11. doi: 10.3109/03008209609000699. Connect Tissue Res. 1996. PMID: 9023049
-
Fourier transform infrared spectroscopy of the solution-mediated conversion of amorphous calcium phosphate to hydroxyapatite: new correlations between X-ray diffraction and infrared data.Calcif Tissue Int. 1996 Jan;58(1):9-16. doi: 10.1007/BF02509540. Calcif Tissue Int. 1996. PMID: 8825233
-
Raman and Fourier Transform Infrared (FT-IR) Mineral to Matrix Ratios Correlate with Physical Chemical Properties of Model Compounds and Native Bone Tissue.Appl Spectrosc. 2017 Oct;71(10):2404-2410. doi: 10.1177/0003702817709286. Epub 2017 Aug 1. Appl Spectrosc. 2017. PMID: 28485618
-
A study of some properties of mineralized turkey leg tendon.Connect Tissue Res. 1992;28(4):263-87. doi: 10.3109/03008209209016820. Connect Tissue Res. 1992. PMID: 1304442 Review.
-
Infrared assessment of bone quality: a review.Clin Orthop Relat Res. 2011 Aug;469(8):2170-8. doi: 10.1007/s11999-010-1751-4. Clin Orthop Relat Res. 2011. PMID: 21210314 Free PMC article. Review.
Cited by
-
Infrared spectroscopic characterization of mineralized tissues.Vib Spectrosc. 2005 Jul 29;38(1-2):107-114. doi: 10.1016/j.vibspec.2005.02.015. Vib Spectrosc. 2005. PMID: 16691288 Free PMC article.
-
Maturational changes in dentin mineral properties.Bone. 2007 May;40(5):1399-407. doi: 10.1016/j.bone.2006.12.061. Epub 2007 Jan 3. Bone. 2007. PMID: 17289453 Free PMC article.
-
Fourier-transform infrared spectroscopic imaging of articular cartilage and biomaterials: A review.Trends Appl Spectrosc. 2013;10:1-23. Trends Appl Spectrosc. 2013. PMID: 31693014 Free PMC article.
-
Polarization control of Raman spectroscopy optimizes the assessment of bone tissue.J Biomed Opt. 2013 May;18(5):55005. doi: 10.1117/1.JBO.18.5.055005. J Biomed Opt. 2013. PMID: 23708192 Free PMC article.
-
Analysis of Interactions Between Pyomelanin and the Extracellular Matrix in an Ex Vivo Turkey Tendon Model.ChemistryOpen. 2025 Jun;14(6):e202500194. doi: 10.1002/open.202500194. Epub 2025 Apr 13. ChemistryOpen. 2025. PMID: 40223377 Free PMC article. Review.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical