Risks related to lack of standardization of tests to detect in vitro metronidazole resistance in Helicobacter pylori

Affiliations

Risks related to lack of standardization of tests to detect in vitro metronidazole resistance in Helicobacter pylori

T H Henriksen et al. Eur J Clin Microbiol Infect Dis. 1996 Jun.

Abstract

The correlation between metronidazole MIC readings obtained in vitro on two different media for two different inoculum dilutions was studied after two, three, and five days of incubation using 20 clinical isolates of Helicobacter pylori. The PDM epsilometer (E test) was used. After two days of incubation, log MIC values on chocolate PDM and Vestfold charcoal medium, a new charcoal medium, showed good correlation. Charcoal media can thus be used for metronidazole sensitivity tests. In terms of double-dilution gradients, prolongation of incubation time from two to three days and change of inoculum dilution from 0.5 to 4 McFarland had little impact when studied separately. However, the combined effect of the two variables was marked. The matching of a sparse inoculum incubated for two days against a heavy inoculum incubated for three days resulted in readings which, for 30% of the pairs, differed by two double-dilution gradients or more. On the other hand, the separate influence of both variables was found to affect the correlation coefficients significantly. Five days of incubation was associated with a poor correlation when the variables on MIC readings was not exposed in a scale of double-dilution gradients because the intervals were too large. For this reason, scales without thresholds are recommended.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Aliment Pharmacol Ther. 1992 Aug;6(4):427-35 - PubMed
    1. Lancet. 1990 Apr 21;335(8695):976-7 - PubMed
    1. J Antimicrob Chemother. 1993 Jan;31(1):65-71 - PubMed
    1. Lancet. 1990 Mar 3;335(8688):539-40 - PubMed
    1. Antimicrob Agents Chemother. 1991 Jun;35(6):1230-1 - PubMed

MeSH terms