Transient in vivo protein adsorption onto polymeric biomaterials
- PMID: 88452
- DOI: 10.1002/jbm.820130405
Transient in vivo protein adsorption onto polymeric biomaterials
Abstract
The adsorption of albumin, gamma-globulin, and fibrinogen was measured on three ex vivo polymeric shunt surfaces [polyvinyl chloride (PVC), Silastic, and segmented polyether urethane (Biomer)] exposed to flowing heparinized, canine blood in vivo. Small amounts of radiolabeled proteins were infused into anesthetized mongrel dogs and the deposition of radioactivity on the walls of femoral arteriovenous shunts was followed with time for two hours following initial blood-polymer contact. Previously, transient in vivo platelet and fibrin deposition onto PVC, Silastic, and Biomer was measured by a similar technique in the absence of anticoagulant. A time-dependent phase of thrombus deposition followed by thromboembolism was observed on the PVC and Silastic shunt surfaces but not on the Biomer surface. In the studies reported here on PVC and Silastic, fibrinogen adsorption was found to predominate initially, though it subsequently desorbed somewhat and was replaced by albumin and gamma-globulin. On Biomer, the adsorption of all three proteins increased with time following initial blood contact and fibrinogen was less prominent initially. The PVC surface was found to become passivated with respect to further thrombogenesis after 60-min exposure to flowing blood, at which time a higher fraction of albumin was present on the surface compared to that at earlier blood contact times. These results indicate that rearrangement of adsorbed protein species occurs with time on polymer surfaces exposed to flowing blood in vivo. Early and predominant fibrinogen adsorption appears to be an important factor in the thrombogenic and embolic events observed on the PVC and Silastic shunt surfaces in vivo.
Similar articles
-
The kinetics of baboon fibrinogen adsorption to polymers: in vitro and in vivo studies.J Biomed Mater Res. 1986 Jul-Aug;20(6):739-72. doi: 10.1002/jbm.820200608. J Biomed Mater Res. 1986. PMID: 3722213
-
Blood compatibility of PEO grafted polyurethane and HEMA/styrene block copolymer surfaces.J Biomed Mater Res. 1990 Sep;24(9):1151-71. doi: 10.1002/jbm.820240903. J Biomed Mater Res. 1990. PMID: 2211743
-
In vivo protein adsorption on polymers: visualization of adsorbed proteins on vascular implants in dogs.J Biomater Sci Polym Ed. 1992;4(2):75-88. J Biomater Sci Polym Ed. 1992. PMID: 1486066
-
Biocompatibility in transfusion medicine.Transfus Sci. 1996 Dec;17(4):481-8. Transfus Sci. 1996. PMID: 10168543 Review.
-
Influence of endogenous albumin binding on blood-material interactions.Ann N Y Acad Sci. 1987;516:78-95. doi: 10.1111/j.1749-6632.1987.tb33032.x. Ann N Y Acad Sci. 1987. PMID: 3326491 Review.
Cited by
-
Total internal reflection/fluorescence photobleaching recovery study of serum albumin adsorption dynamics.Biophys J. 1981 Mar;33(3):455-67. doi: 10.1016/S0006-3495(81)84906-5. Biophys J. 1981. PMID: 7194696 Free PMC article.
-
Effect of foreign surface pacification with albumin, aprotinin, propofol, and high-density lipoprotein.J Extra Corpor Technol. 2009 Mar;41(1):3-9. J Extra Corpor Technol. 2009. PMID: 19361025 Free PMC article.
-
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.J Exp Med. 1993 Dec 1;178(6):2147-56. doi: 10.1084/jem.178.6.2147. J Exp Med. 1993. PMID: 8245787 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources