Ventilation-perfusion inequality in nocturnal hypoxaemia due to chronic obstructive lung disease (COLD)
- PMID: 8846670
- DOI: 10.1111/j.1475-097x.1995.tb00539.x
Ventilation-perfusion inequality in nocturnal hypoxaemia due to chronic obstructive lung disease (COLD)
Abstract
Nocturnal hypoxaemia is often noted in COLD patients with a daytime PaO2 above 8.0 kPa. It has been assumed that ventilation-perfusion inequality contributes to nocturnal hypoxaemia. 10 patients with advanced COLD [median FEV1 0.73 (range 0.50-1.32)l], but without daytime hypoxaemia [median PaO2 8.35 (range 8.0-12.2) kPa] were investigated with regard to possible nocturnal hypoxaemia using polysomnography. Daytime lung function was assessed by spirometry and carbon monoxide diffusion capacity (DLCO). Daytime ventilation-perfusion (VA/Q) relationships were measured by the multiple inert gas elimination technique. Dispersion of perfusion and ventilation distributions was increased [log SDQ 1.01 (range 0.80-1.35) and log SDV 0.91 (range 0.69-1.86) resp.]. Around 8% of the ventilation was directed towards high VA/Q areas (10 < VA/Q < 100). All subjects reached all sleep stages, and all but one had a nadir nocturnal oxygen saturation (SaO2) of below 90%. Their median lowest nocturnal SaO2 was 84.0 (range 70-93)% and their mean oxygen saturation in the course of desaturation episodes (MminSaO2) was 86.4 (range 83.6-91.5)%. An increased mean VA/Q ratio of ventilation distribution was associated with a reduced DLCO. Increased nocturnal episodes of wakefulness and of stage I sleep correlated with increased dead space ventilation and dispersion of the ventilation distribution. Patients with deep nocturnal desaturations had a low mean VA/Q ratio of the perfusion distribution (Q mean) (r = 0.87, P < 0.01) and increased perfusion of inferior VA/Q areas (0.1 VA/Q < 0.3). Low MminSaO2 was associated with low morning PaO2 and a low Q mean. COLD patient with solely nocturnal hypoxaemia have a high degree of pulmonary hyperinflation and emphysema. Increased sleep disruption is associated with more severe small airway disease. Increased perfusion of sparsely ventilated areas is associated with more pronounced nocturnal desaturations.
Similar articles
-
Sleep quality, carbon dioxide responsiveness and hypoxaemic patterns in nocturnal hypoxaemia due to chronic obstructive pulmonary disease (COPD) without daytime hypoxaemia.Respir Med. 1999 Feb;93(2):79-87. doi: 10.1016/s0954-6111(99)90295-0. Respir Med. 1999. PMID: 10464857
-
Predictors for nocturnal hypoxaemia (mean SaO2 < 90%) in normoxic and mildly hypoxic patients with COPD.Eur Respir J. 1995 Jan;8(1):74-7. doi: 10.1183/09031936.95.08010074. Eur Respir J. 1995. PMID: 7744197
-
Ventilation-perfusion inequality in patients with non-alcoholic liver cirrhosis.Eur Respir J. 1991 Jun;4(6):711-7. Eur Respir J. 1991. PMID: 1889498
-
Sleep and chronic obstructive pulmonary disease.Sleep Med Rev. 2004 Aug;8(4):281-94. doi: 10.1016/j.smrv.2004.03.006. Sleep Med Rev. 2004. PMID: 15233956 Review.
-
Sleep-related hypoxaemia in chronic obstructive pulmonary disease: causes, consequences and treatment.Respiration. 1997;64(3):187-93. doi: 10.1159/000196669. Respiration. 1997. PMID: 9154669 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical