Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Sep;3(9):827-31.
doi: 10.1111/j.1553-2712.1996.tb03526.x.

Subarachnoid hemorrhage diagnosis: lumbar puncture is still needed when the computed tomography scan is normal

Affiliations
Free article

Subarachnoid hemorrhage diagnosis: lumbar puncture is still needed when the computed tomography scan is normal

R Sidman et al. Acad Emerg Med. 1996 Sep.
Free article

Abstract

Objectives: To determine the sensitivity of third-generation CT scanners for diagnosed nontraumatic subarachnoid hemorrhage (SAH) and to assess the impact of symptom duration on sensitivity.

Methods: A retrospective chart review was performed in a university-affiliated tertiary care hospital with an annual ED volume of > 100,000 patients. The target population was all patients who presented to the ED from January 1991 to September 1994 with symptoms suggestive of SAH and who had a final diagnosis of nontraumatic SAH based on either a positive CT scan or positive spinal fluid analysis. Patients referred from outside facilities were included if they had a CT done at the study site. All CT scans were done using third-generation scanners. Official CT scan reports were used to categorize scans as positive or negative.

Results: There were 140 patients identified with SAH, with a mean age of 56 years (range 10-88). The sensitivity of CT in the diagnosis of nontraumatic SAH when performed at or before 12 hours of symptom duration was 100% (80/80), and 81.7% (49/60) after 12 hours of symptom duration (95% CI 95-100% and 69.5-90.4%, respectively; p < 0.0001). Eleven of the 140 patients had a negative CT and positive spinal fluid analysis, yielding an overall sensitivity of 92.1% (129/140).

Conclusion: The sensitivity of third-generation CT scans for SAH decreases with time from the onset of symptoms. In this sample population, CT was able to detect all patients scanned < or = 12 hours after symptom onset. Although the study demonstrated good sensitivity of CT scan reports for SAH when the scan was performed after < or = 12 hours of symptom onset, additional real-time experience is needed to better define the potential risk of a missed SAH should this population not receive the customary lumbar puncture examination in the setting of a negative CT scan.

PubMed Disclaimer

Comment in

  • A tap in time?
    Singal BM. Singal BM. Acad Emerg Med. 1996 Sep;3(9):823. doi: 10.1111/j.1553-2712.1996.tb03523.x. Acad Emerg Med. 1996. PMID: 8870750 No abstract available.